基于力传感器的核电厂电缆绝缘老化检测分析  被引量:2

Detection and Analysis of Cable Insulation Aging in Nuclear Power Plant Based on Force Sensor

在线阅读下载全文

作  者:朱斌[1] 陈忻 惠兆宇[1] 刘韬[1] 雷毅 ZHU Bin;CHEN Xin;HUI Zhaoyu;LIU Tao;LEI Yi(Suzhou Nuclear Power Research Institute Co.,Ltd,Suzhou 215004,China)

机构地区:[1]苏州热工研究院有限公司

出  处:《电工材料》2020年第1期17-19,共3页Electrical Engineering Materials

摘  要:针对核电厂内错综复杂的仪控电缆服役时间较长,电缆绝缘和护套材料易发生老化的问题,对服役期内电缆绝缘材料进行无损老化检测设计。该设计方案采用力传感器测量绝缘材料的力与压痕深度,形成老化指数评估老化状态。测试结果表明,该检测方案可以有效检测和评价电缆绝缘老化状态,且无损于待测电缆。In view of the long service time of the complex instrument and control cable in the nuclear power plant and the easy aging of the cable insulation and sheath materials,the insulation material of cable in the service period is designed for nondestructive aging test.The design uses force sensor to measure the depth of indentation and depth of insulation material,and form aging index to evaluate aging state.The test results show that the detection scheme can effectively detect and evaluate the aging status of cable insulation,and it is not harmful to the cable to be tested.

关 键 词:力传感器 老化检测 核电 

分 类 号:TM930[电气工程—电力电子与电力传动]

 