Improvements to the retractor and muscle flap design for minimally invasive cochlear implantation  被引量:1

Improvements to the retractor and muscle flap design for minimally invasive cochlear implantation

在线阅读下载全文

作  者:Riyuan Liu Zhiping Tan Jianan Li Yan Yan Wei Ren Miao Zhang Shiming Yang Hui Zhao 

机构地区:[1]Department of Otolaryngology Head and Neck Surgery,Institute of Otolaryngology,Chinese PLA General Hospital,China National Clinical Research Center for Otolaryngologic Diseases,Beijing,100853,China [2]Zhejiang Nurotron Biotechnology Company Limited,Hangzhou,Zhejiang,311121,China

出  处:《Journal of Otology》2020年第1期41-44,共4页中华耳科学杂志(英文版)

基  金:supported by the Special Funds for National Excellent Doctoral Dissertation of Higher Education from the Ministry of Education (Project Number: 2007B67);the National Major Research Project (2014CB943003)

摘  要:Objective: The aim of this study was to improve muscle flaps and to evaluate surgical outcomes with the use of a novel specialized retractor, which is a surgical instrument used to locate and shape a bony seat for minimally invasive cochlear implantation.Methods: 50 patients aged 1 e75 years with sensorineural hearing loss who required cochlear implantation were recruited. A small incision(<3 cm) was made, and the novel specialized retractor was used in the study group during cochlear implantation. The incision length, surgical outcomes and operative time were recorded and analyzed.Results: The incision length, total operative time and drilling bony time were shorter in the study group than in the control group(P < 0.05, respectively). All patients recovered well after the surgery without any severe complications.Conclusion: The use of a novel specialized retractor standardized the surgical processes of cochlear implantation. The retractor helped locate and control the size of the bony well during bone drilling. The tool reduced the technical difficulty and improved the efficacy of this minimally invasive operation.Objective: The aim of this study was to improve muscle flaps and to evaluate surgical outcomes with the use of a novel specialized retractor, which is a surgical instrument used to locate and shape a bony seat for minimally invasive cochlear implantation.Methods: 50 patients aged 1 e75 years with sensorineural hearing loss who required cochlear implantation were recruited. A small incision(<3 cm) was made, and the novel specialized retractor was used in the study group during cochlear implantation. The incision length, surgical outcomes and operative time were recorded and analyzed.Results: The incision length, total operative time and drilling bony time were shorter in the study group than in the control group(P < 0.05, respectively). All patients recovered well after the surgery without any severe complications.Conclusion: The use of a novel specialized retractor standardized the surgical processes of cochlear implantation. The retractor helped locate and control the size of the bony well during bone drilling. The tool reduced the technical difficulty and improved the efficacy of this minimally invasive operation.

关 键 词:Minimally invasive surgery Cochlear implantation RETRACTOR Muscle flap 

分 类 号:R764.9[医药卫生—耳鼻咽喉科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象