检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:郑名 曹思敏[1] 刘阳依 曹潇丹[1] 陈壮 闫姝君 李昊阳 陈缙泉 徐建华[1] ZHENG Ming;CAO Si-min;LIU Yang-yi;CAO Xiao-dan;CHEN Zhuang;YAN Shu-jun;LI Hao-yang;CHEN Jin-quan;XU Jian-hua(State Key Laboratory of Precision Spectroscopy,East China Normal University,Shanghai 200062,China)
机构地区:[1]华东师范大学精密光谱科学与技术国家重点实验室
出 处:《光谱学与光谱分析》2020年第3期813-816,共4页Spectroscopy and Spectral Analysis
基 金:国家自然科学基金委面上项目基金(11674101,21873030)资助
摘 要:锌离子Zn^2+对胆红素BR有着显著的荧光增强效应,基于该荧光特性,利用紫外可见光吸收和稳态荧光光谱技术提出了一种BR作为荧光探针用于Zn^2+浓度检测的新方法,特别是首次采用在波长663和600nm处的稳态荧光强度比值方法系统地研究了其与锌离子浓度在0~90μmol·L^-1范围内变化的关系,与常用的单波长荧光强度探测方法比较,有效地避免了探针浓度变化及激发光强度变化等非目标因素的影响。实验研究结果发现BR荧光探针对Zn^2+的识别行为在0~20μmol·L^-1范围内,探针BR的荧光强度比值I663 nm/I600 nm与Zn^2+的浓度之间具备线性增长关系,尤其是0~10μmol·L^-1有非常好的线性关系,线性相关系数r=0.999 87,同时Zn^2+检测限为0.1μmol·L^-1。在20~90μmol·L^-1范围内,荧光强度比值I663 nm/I600 nm趋于饱和。研究发现对实时检测人体内的Zn^2+具有很好的应用前景。Based on the fluorescence enhancement effect of Zn^2+ on bilirubin(BR), this work proposes a new method for the detection of Zn^2+ concentration, and a systematically investigation of BR as a Zn^2+ probe by using ultraviolet-visible light absorption and steady-state fluorescence spectroscopy has been conducted. Compared with the general single-wavelength fluorescence intensity method, this new detection method eliminates the impacts of the non-target effects of factors such as concentration variation of BR and the excitation light intensity, etc., and achieves a more accurate measurement capability in Zn^2+ detection. Especially, for the first time we adopt the BR fluorescence intensities ratio at the emission wavelengths 663 and 600 nm, and investigate the dependence between this ratio and the Zn^2+ concentration in the range from 0 to 90 μmol·L^-1. The recognition behavior of BR probe to Zn^2+ indicates that the BR fluorescence intensity ratio I663 nm/I600 nm increases linearly with the Zn^2+ concentration in the range of 0~20 μmol·L^-1. In particular, in the range 0~10 μmol·L^-1 of Zn^2+ concentration, the linear correlation coefficient r is 0.999 87, which demonstrates the linear dependence, and the detection limit is 0.1 μmol·L^-1. In the Zn^2+ concentration range from 20 to 90 μmol·L^-1, the probe BR fluorescence intensity ratio is saturated. Accordingly, there is a positive prospect of BR fluorescence in the real-time human body Zn^2+ detection.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.148.221.111