上颌前牙区不同种植修复体在不同咬合受力下的三维有限元分析  被引量:20

Three-dimensional finite element analysis of different implant prostheses in maxillary anterior teeth region under different occlusal relationships

在线阅读下载全文

作  者:安尼卡尔·安尼瓦尔 帕丽黛姆·图尔迪 阿迪力·麦木提敏 张帆[1] 尼加提·吐尔逊[1] Annikaer·Aniwaer;Palidaimu·Tuerti;Adili·Maimutimin;Zhang Fan;Niruti·Tuerxun(Department of Stomatology,the Second Affiliated Hospital of Xinjiang Medical University,Urumqi 830063,Xinjiang Uygur Autonomous Region,China)

机构地区:[1]新疆医科大学第二附属医院口腔科

出  处:《中国组织工程研究》2020年第16期2531-2536,共6页Chinese Journal of Tissue Engineering Research

基  金:新疆维吾尔自治区自然科学基金(2016D01C192),课题名称:维药买朱尼对种植体周围炎龈沟液中IL-1β以及骨界面改建影响的实验研究,项目负责人:尼加提·吐尔逊~~

摘  要:背景:在口腔种植修复治疗中,修复因素与咬合因素影响着植体内部结构及植体-骨界面处应力的分布,植体内部结构及植体-骨界面处应力分布是否平衡决定着种植体的长期寿命与周围骨质水平的稳定性。目的:探讨与分析二氧化锆全瓷冠与钴铬合金烤瓷冠修复体在3种咬合关系中对植体-骨界面处、种植体、修复基台、固位螺丝及修复体内部应力分布的影响。方法:参照1例上颌中切牙区行种植体植入修复患者的锥形束CT影像资料,运用Mimics17.0软件建立上颌中切牙种植修复体模型,分别构建二氧化锆全瓷冠与钴铬合金烤瓷冠两种三维有限元模型,模拟对刃合、正常合、深覆合3种咬合状况进行加载,分析在2种修复体与3种加载方式影响下种植体内部各结构与种植体-骨界面的应力分布情况。结果与结论:①在钴铬合金烤瓷冠组中,当咬合关系由对刃合转变为正常合及深覆合时,修复体咬合位点处应力相应增加,而修复基台、种植体边缘及植体-骨界面处的应力减小;正常咬合关系中固位螺丝处的应力较其他两种咬合方式更为集中,等效应力峰值更高。②在二氧化锆全瓷冠组中,当咬合关系由对刃合转变为正常合及深覆合时,修复基台、种植体及种植体-骨界面的应力峰值呈逐渐下降趋势;正常合时修复体咬合位点及固位螺丝处的应力峰值高于其他两种咬合关系。③对刃合时,钴铬合金烤瓷冠组修复体咬合位点处的等效应力峰值略高于二氧化锆全瓷冠组,修复基台、固位螺丝、种植体与种植体-骨界面的等效应力峰值略低于二氧化锆全瓷冠组;正常合时,钴铬合金烤瓷冠组种植体颈部处的等效应力峰值略高于二氧化锆全瓷冠组,修复体、修复基台、固位螺丝、种植体-骨界面的等效应力峰值略低于二氧化锆全瓷冠组;深覆合时,钴铬合金烤瓷冠组修复体咬合位点处及种植体颈BACKGROUND: In the treatment with dental implant prosthesis, the stress distribution of marginal bone and implant-bone interface is affected by the factors of restoration and occlusion. The internal structure and the stress distribution of implant-bone interface determine the long-term life of the implant and the stability of the marginal bone. OBJECTIVE: To analyze the effects of zirconia-based all-ceramic crown and Co-Cr alloy porcelain ceramic crown on the stress distribution of implant-bone interface, implant, prosthesis abutment, retention screw, and the inner structure in three occlusal relationships. METHODS: Using Mimics 17.0 software, the implant model of maxillary central incisor was established based on the cone beam CT of a patient undergoing prosthesis implantation into the maxillary central incisor. Two kinds of three-dimensional finite element models of zirconia-based all-ceramic crown and Co-Cr alloy porcelain ceramic crown were constructed. The edge to edge occlusion, normal occlusion and deep overbite were simulated to analyze the stress distribution of implant structure and the implant-bone interface in the three occlusal relationships. RESULTS AND CONCLUSION:(1) In the Co-Cr alloy porcelain ceramic crown group, when the occlusal relationship changed from the edge-to-edge occlusion to the normal occlusion and deep overbite relationships, the stress at the occlusal point of the prosthesis increased correspondingly, and the stress at the abutment, implant and the implant-bone interface decreased. In the normal occlusal relationship, the stress at the retention screw was more concentrated than that in the other two occlusal relationships, and its peak value of the equivalent stress was higher.(2) In the zirconia-based all-ceramic crown group, when the occlusal relationship changed from edge-to-edge occlusion to the normal and deep overbite relationships, the stress peaks of the abutment, implant and implant-bone interface decreased gradually. In the normal occlusal relationship, the stress peaks o

关 键 词:种植修复体 前牙美学区 咬合 修复体 生物力学 应力 三维有限元 咬合力 有限元分析 组织工程 

分 类 号:R459.9[医药卫生—治疗学] R783.4[医药卫生—临床医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象