作 者:刘海峰 毛文奇 梁文武 鲁文军[3] 傅明[3] LIU Haifeng;MAO Wenqi;LIANG Wenwu;LU Wenjun;FU Ming(Electric Power Research Institute,State Grid Hunan Electric Power Company Limited,Changsha 410007,China;State Grid Hunan Electric Power Company Limited,Changsha 410004,China;College of Electrical and Information Engineering,Hunan University,Changsha 410082,China)
机构地区:[1]国网湖南省电力有限公司电力科学研究院,长沙410007 [2]国网湖南省电力有限公司,长沙410004 [3]湖南大学电气及信息工程学院,长沙410082
出 处:《电力系统及其自动化学报》2019年第12期89-94,共6页Proceedings of the CSU-EPSA
基 金:国家电网公司总部科技资助项目(5216A0180003)。
摘 要:10 kV开关柜事故绝大部分是开关柜内部或者外部架空电缆发生单相接地导致非故障相相电压升高致使开关柜发生弧光放电引起的。为了提高10 kV开关柜运行的安全稳定性,在10 kV开关柜发生单相接地故障并伴有弧光放电时常规保护不动作且电流闭锁弧光保护不动作的基础上,提出了一种新型基于电压闭锁原理的10 kV开关柜弧光保护。电压闭锁型弧光保护不同于常规电流闭锁型弧光保护,其采用电压和弧光双判据,并将电压闭锁型弧光保护与常规电流闭锁式弧光保护做比较,通过仿真和事故实例得出在10 kV开关柜中新型电压闭锁原理的弧光保护比常规电流闭锁原理的弧光保护具有更高的灵敏度。Most of the accidents related to a 10 kV switchgear are caused by arc discharge within the switchgear,which is due to the rise in non-fault phase voltage resulting from single-phase grounding of overhead cables inside or outside the switchgear.To improve the safety and stability of the switchgear operation,on the basis of analyzing the non-actions of the conventional protection and current lockout arc protection when the single-phase grounding fault occurs in the 10 kV switchgear(also accompanied by arc discharge),a novel type of arc protection scheme for the 10 kV switchgear is proposed based the principle of voltage lockout,which is different from the conventional current lockout arc protection.This scheme adopts double criteria of voltage and arc,and it is further compared with the conventional current lockout arc protection.Through simulations and examples of real accident,it is concluded that the arc protection scheme based on the novel voltage lockout principle has higher sensitivity than that based on the conventional current lockout principle.
关 键 词:电压闭锁 弧光保护 绝缘放电 电流闭锁 单相接地 10 kV开关柜 中性点不接地
分 类 号:TM771[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.220.9.72