检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:高本锋 王飞跃 于弘洋 赵国亮 邵冰冰 赵书强 Gao Benfeng;Wang Feiyue;Yu Hongyang;Zhao Guoliang;Shao Bingbing;Zhao Shuqiang(Key Laboratory of Distributed Energy Storage and Microgrid of Hebei Province North China Electric Power University,Baoding 071003 China;State Key Laboratory of Advanced Transmission Technology Global Electricity Interconnection Research Institute,Beijing 102200 China)
机构地区:[1]分布式储能与微网河北省重点实验室(华北电力大学),保定071003 [2]全球能源互联网研究院有限公司先进输电技术国家重点实验室,北京102200
出 处:《电工技术学报》2020年第6期1346-1356,共11页Transactions of China Electrotechnical Society
基 金:国家电网公司科技项目“串联型次同步振荡抑制器关键技术研究”(GEIRI-DL-71-18-005);教育部中央高校基本科研业务费专项基金(2018MS087)资助项目。
摘 要:针对双馈风电场经串补系统外送功率时存在次同步控制相互作用(SSCI)问题,该文提出一种应用静止同步串联补偿器(SSSC)抑制SSCI的等效正电阻控制方法。该方法采用网侧线路中的电流作为输入信号,通过SSSC附加有源电阻控制(SARC)策略生成与线路中次同步电流同相位的次同步电压信号。SSSC实时跟踪该次同步电流信号,使其在次同步频率下等效为一正电阻。通过在网侧串接SSSC使网侧电阻增大,从而系统等值电阻被抬升至正值区域,进而达到抑制SSCI的效果。此外,详细介绍了SARC的结构及参数设计方法。最后,在PSCAD/EMTDC上搭建了华北某实际风电场时域仿真模型。仿真结果表明:多种运行工况下,SSSC可等效成正电阻使系统等值电阻处在正值区域,从而避免了系统发生SSCI。该方法具有参数整定简便、便于实现等优点。In view of the problem of sub-synchronous control interaction(SSCI)when the doubly-fed wind farms transmit power through the series-compensated system,this paper proposes an equivalent positive resistance control method based on SSSC to suppress SSCI.The method uses the current in the grid side as an input signal and produces sub-synchronous voltage reference signal corresponding to sub-synchronous current in the line through the SSSC supplementary active resistance control(SARC)strategy.The SSSC traces sub-synchronous current to make it equivalent to a positive resistance at the sub-synchronous frequency.The grid side resistance is increased by connecting the SSSC in the line,and the system equivalent resistance is increased to a positive value region,thereby mitigating SSCI.In addition,the structure and parameter design method of SARC are introduced in detail.Finally,based on an actual wind farm structure in North China,the simulation model was built in PSCAD/EMTDC.The results show that the system equivalent resistance is in the positive region because SSSC is equivalent to a positive resistance under various operating conditions,thereby avoiding SSCI in the system.The method has advantages of simple parameters setting and easy realization.
关 键 词:双馈风电场 串补系统 次同步控制相互作用 SSSC 附加有源电阻控制
分 类 号:TM712[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.218.10.21