某型雷达发射电源输出不转换问题分析与改进  

Analysis and Improvement of Malfunction in Whichpower Does Not Convert

在线阅读下载全文

作  者:肖鹏斌[1] 刘佳[1] XIAO Peng-bin;LIU Jia(Naval equipment department,Gansu Lanzhou 730070,China)

机构地区:[1]海军装备部,甘肃兰州730070

出  处:《移动电源与车辆》2019年第4期48-49,52,共3页Movable Power Station & Vehicle

摘  要:针对某型雷达在试验过程中出现发射电源11 V/5.5 V输出不转换的现象,发现前期对发射电源的过流、过压保护功能参数进行过调整,定位故障件为R34电阻阻值开路失效.通过建立故障模型进行分析,确定为机械应力累积导致,调整改进工艺后重新测试.结果满足技术指标要求,验证了改进的正确性。For the phenomenon that the 11V/5.5V output of the transmitting power is not converted during the test,it is found that the over-current and over-voltage protection function parameters of the transmitting power supply have been adjusted in the early stage. The faulty component is located in the open-circuit failure of the R34 resistor value,and is analyzed by establishing a fault model to determine the accumulation of mechanical stress. After re-testing after adjusting the improved process,the results meet the requirements of the technical indicators and verify the correctness of the improvement.

关 键 词:输出不转换 故障诊断与定位 机理分析 

分 类 号:TM611.2[电气工程—电力系统及自动化]

 