检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李文华 鲍听 沈利 王来邦 杨毅均 张光学[4] LI Wenhua;BAO Ting;SHEN Li;WANG Laibang;YANG Yijun;ZHANG Guangxue(Zhejiang Zheneng Wenzhou Power Generation Co.,Ltd.,Wenzhou 325602,China;Zhejiang Energy Group R&D,Hangzhou 310003,China;Zhejiang Zheneng Electric Power Co.,Ltd.,Hangzhou 310003,China;Institute of Energy Engineering,China Jiliang University,Hangzhou 31001&China)
机构地区:[1]浙江浙能温州发电有限公司,浙江温州325602 [2]浙江浙能技术研究院有限公司,浙江杭州310003 [3]浙江浙能电力股份有限公司,浙江杭州310003 [4]中国计量大学能源工程研究所,浙江杭州310018
出 处:《热力发电》2020年第3期118-123,共6页Thermal Power Generation
基 金:国家重点研发计划项目(2017YFF0205006);国家自然科学基金项目(51876197)。
摘 要:蒸汽吹灰器在燃煤电站锅炉的应用非常广泛,但由于蒸汽温度高、动量大,加上有时因过热度不足或疏水不充分使吹灰射流带水,因此对受热面热冲击较大,常发生吹损管壁等事故。对此,本文以浙江某电厂660 MW机组锅炉管式GGH烟气冷却器吹灰系统为研究对象,提出了将吹灰工质改为1.2 MPa压缩空气,并将喷嘴改为内径为14 mm的文丘里缩放喷嘴的改造方案。数值模拟结果表明,采用喉口直径为14 mm的文丘里喷嘴时,压缩空气射流刚性很强,最高速度为2.1马赫,有效吹灰距离可以达到改造前的80%。从实际运行数据看,采用压缩空气吹灰的换热器模块阻力小于蒸汽吹灰的模块阻力,吹灰系统运行良好,未再发生管壁吹损问题。Steam soot blowing systems are widely applied in coal-fired boilers.However,due to high temperature,huge kinetic energy and sometimes entrained water droplets caused by insufficient superheat degree or insufficient drainage water,it will cause large thermal impact on the heating surface,which leads to frequent wear out of tube walls.To solve this problem,the soot-blowing system retrofitting for tubular gas-gas heater(GGH)of a 660 MW unit boiler in a Zhejiang power plant has been implemented.In the retrofitting,the compressed air(1.2 MPa)is employed in the soot blowing system instead of steam,and the spraying nozzle is changed into Venturi contraction and enlargement nozzle with inner diameter of 14 mm.The numerical simulation shows that,when using the Venturi nozzle with throat diameter of 14 mm,the jet air flow has a strong rigidity and a maximum velocity of 2.1 Mach.The efficient soot-blowing distance after the retrofitting reaches 80%of that before the retrofitting.The practical operation data indicate that the pressure drops of the tubular gas-gas heater using the compressed air soot-blowing system are less than that using the steam soot blowing system,the compressed air soot blowing system is in good operation and no pipe wall blowing loss occurs.
关 键 词:吹灰器 压缩空气 蒸汽 吹灰系统 管式GGH 数值模拟
分 类 号:TK227.3[动力工程及工程热物理—动力机械及工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.188