作  者:原效凯[1] 李巍 毕芳[1] 苏昭忠[1] 张志贤 YUAN Xiao-kai;LI Wei;BI Fang;SU Zhao-zhong;ZHANG Zhi-xian(Architectural Design and Research Institute of Guangdong Province,Guangzhou 510010,China)

机构地区:[1]广东省建筑设计研究院,广东广州510010

出  处:《中国给水排水》2020年第4期114-118,共5页China Water & Wastewater

摘  要:湖南某化工农药产业基地污水处理厂提标改造工程处理规模为2.0×10^4 m^3/d,在充分分析现有污水厂处理工艺、进出水指标以及运行状况的基础上,采用高级氧化前置预处理+强化生化+后置高级氧化+深度处理工艺进行提标改造,出水水质稳定达到《城镇污水处理厂污染物排放标准》(GB 18918-2002)的一级A标准,直接运行费用为8.004元/m^3。The design capacity of upgrading and reconstruction project of a chemical pesticide wastewater treatment plant(WWTP)in Hunan Province is 2.0×10^4 m^3/d.Based on the comprehensive analysis of the existing process,influent and effluent quality indexes and operation of the WWTP,the upgraded project integrated the technology of advanced oxidation pretreatment,enhanced biochemical,post-stage advanced oxidation and advanced treatment.The effluent quality met the first level A criteria in Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant(GB 18918-2002),with the direct operating cost of 8.004 yuan/m^3.

关 键 词:化工农药废水 芬顿 曝气生物滤池 

分 类 号:TU993[建筑科学—市政工程]

 