老年冠心病患者心肌缺血和心律失常诊断中12导联动态心电图的价值研究  被引量:6

Value of 12-lead Dynamic Electrocardiogram in Diagnosis of Myocardial Ischemia and Arrhythmia in Elderly Patients with Coronary Heart Disease

在线阅读下载全文

作  者:肖旋[1] 翟振海 XIAO Xuan;ZHAI Zhen-hai(Weihai Municipal Second Hospital Affiliated to Qingdao University 264200(Weihai,Shandong)

机构地区:[1]青岛大学附属威海市立第二医院,山东威海264200

出  处:《中国医药指南》2020年第9期29-30,共2页Guide of China Medicine

摘  要:目的本次研究分析在老年冠心病患者心肌缺血与心律失常诊断中采用12导联动态心电图的应用价值。方法本次研究样本从本院100例老年冠心病患者中选取,研究时间从2018年3月开始,截至2019年3月。将诊断方式作为分组依据,实验组患者采用3导联Holter检测,对照组患者采用12导联Holter检测,对比两组诊断结果。结果统计两组患者心肌缺血阳性检出率,分析得知,实验组患者心肌缺血阳性检出率较高,两组患者对比符合统计学标准(P<0.05);统计两组患者心律失常阳性检出率,分析得知,实验组患者心律失常阳性检出率较高,两组对比符合统计学标准(P<0.05)。统计两组患者心律失常阳性情况,分析得知,实验组患者心律失常阳性情况较优异,两组对比符合统计学标准(P<0.05)。结论通过此次研究证实,在老年冠心病患者心肌缺血与心律失常诊断中采用12导联动态心电图,能提高诊断价值,改善患者诊断准确率。Objective This study analyzed the application value of 12-lead dynamic electrocardiogram in the diagnosis of myocardial ischemia and arrhythmia in elderly patients with coronary heart disease.Methods The study sample was selected from 100 elderly patients with coronary heart disease in our hospital.The study period began in March 2018 and ended in March 2019.The diagnostic method was used as grouping basis.The experimental group was detected by 3-lead Holter test,while the control group was detected by 12-lead Holter test.The diagnostic results of the two groups were compared.Result The positive detection rate of myocardial ischemia in the two groups was statistically analyzed.The positive detection rate of myocardial ischemia in the experimental group was higher than that in the control group(P<0.05);the positive detection rate of arrhythmia in the two groups was statistically analyzed.It was found that the positive detection rate of arrhythmia in the experimental group was higher,and the comparison between the two groups was in accordance with the statistical standard(P<0.05).Statistical analysis showed that the positive rate of arrhythmia in the experimental group was better than that in the control group,and the comparison between the two groups accorded with the statistical standard(P<0.05).Conclusion This study confirmed that 12-lead dynamic electrocardiogram can improve the diagnostic value and diagnostic accuracy of elderly patients with coronary heart disease in the diagnosis of myocardial ischemia and arrhythmia.

关 键 词:冠心病 心肌缺血 心律失常 12导联动态心电图 

分 类 号:R541.4[医药卫生—心血管疾病]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象