甲基肼和偏二甲基肼水含量标准物质的定值方法研究  被引量:1

Study on determination method for water content reference materials of methylhydrazine and unsymmetrical dimethylhydrazine

在线阅读下载全文

作  者:赵坦 徐林楠 龚维[2] 毛亚南[1] 宋磊 李俊[1] Zhao Tan;Xu Linnan;Gong Wei;Mao Yanan;Song Lei;Li Jun(Beijing Institute of Aerospace Testing Technology,Beijing 100074,China;Institute 53 of China Ordnance Industry Group,Jinan 250031,China)

机构地区:[1]北京航天试验技术研究所,北京100074 [2]中国兵器工业集团第五三研究所,山东济南250031

出  处:《化学推进剂与高分子材料》2020年第2期58-63,共6页Chemical Propellants & Polymeric Materials

基  金:国防基础科研计划(800003)。

摘  要:通过优化甲基肼(MMH)和偏二甲基肼(UDMH)的水含量气相色谱分析方法,实现对研制的MMH和UDMH水含量标准物质标称值的测定。为提高定值准确度,同时采用气相色谱标准加入法和液体水分标准物质校正法对影响水含量定值结果的因素进行研究。结果表明:气相色谱标准加入法的标准曲线线性关系良好,相关系数R2均大于0.999;2种方法定值结果偏差较小,F检验和T检验表明2种定值方法测定结果无显著差异。该标准物质对MMH和UDMH水含量的量值传递和量值溯源具有重要意义。By optimizing the gas chromatographic analysis method for water content of methylhydrazine(MMH)and unsymmetrical dimethylhydrazine(UDMH),the determination of the nominal values of the water content reference materials of the prepared MMH and UDMH was achieved.Meanwhile,in order to improve the accuracy of the determination,the factors affecting the determination results were investigated by using the gas chromatographic standard addition method and the liquid water reference material correction method.The results show that the standard curves of the gas chromatographic standard addition method exhibit good linearity,the correlation coefficient R2 is all greater than 0.999;the deviations of determination results of two methods are small,the F test and T test show that the determination results of two determination methods have no significant difference.The reference material possesses great significance for the magnitude transfer and magnitude traceability of the water content of MMH and UDMH.

关 键 词:甲基肼 偏二甲基肼 水含量 标准物质 气相色谱法 

分 类 号:TQ014[化学工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象