220 kV变压器箱沿螺栓发热理论分析和现场处理  被引量:6

Theoretical Analysis and Field Treatment of Bolt Heating Along the Edge of Fuel Tank in 220 kV Transformer

在线阅读下载全文

作  者:张彦 张宇巍 杨旻宸 黄佳骏 蔡磊 ZHANG Yan;ZHANG Yuwei;YANG Minchen;HUANG Jiajun;CAI Lei(South Power Supply Company,SMEPC,Shanghai 200030,China)

机构地区:[1]国网上海市电力公司市南供电公司,上海200030

出  处:《高压电器》2020年第3期247-252,共6页High Voltage Apparatus

摘  要:为了解决220 kV变压器箱沿螺栓异常发热问题,先分析红外跟踪数据并总结箱沿螺栓的发热特点,从理论上推导变压器漏磁在箱沿螺栓上产生的涡流损耗数学表达式,根据表达式得出螺栓发热的3个特点,然后根据分析结果,依次采用螺栓替换和加装短接铜排的方法进行处理,结果表明,该法实用性强,能有效消除变压器箱沿螺栓异常发热隐患。In order to solve the problem which part of bolts along the edge of fuel tank were abnormal heat in 220 kV transformer,the data of infrared lock-on was analyzed and the heating characteristics of the bolts were summarized firstly.Then the mathematical expression of the eddy current loss generated by the magnetic flux leakage of transformer on the bolts along the edge of fuel tank was deduced theoretically.According to the mathematical expression,the three heating characteristics of bolt were obtained.With the result,the bolt replacement and installation of the short connection were used in turn to deal with this problem.It showed that the method was practical and could eliminate the abnormal heating hazard of bolts along the edge of transformer fuel tank.

关 键 词:变压器 漏磁 螺栓 异常发热 分析处理 

分 类 号:TM407[电气工程—电器]

 