摘  要:长期以来,贵州华电桐梓发电有限公司冷态启动耗油量大部分在90 t以上,锅炉从点火到油枪全部撤出时间在12 h以上,严重影响了机组经济性。为了降低机组启动耗油量,节约成本,在市场调研的基础上,从煤质选配、启动环节管理把控,使冷态启动耗油量降至40 t以下,对同类型机组启动具有一定的借鉴意义。For a long time,the fuel consumption of cold start in tongzi company is more than 90 t,and the time from ignition to withdrawal of the oil gun is more than 12 h,which affects the unit economy.In order to reduce the fuel consumption and the start-up cost of the unit,it controls the coal quality selection and the start-up management on the basis of the market research.It reduces the fuel consumption of cold start-up below 40 t,which has certain reference significance for the start-up of similar units.