作  者:陈乐[1] 强天鹏 盛佩军 胥杨[1] CHEN Le;QIANG Tianpeng;SHENG Peijun;XU Yang(Shanghai Institute of Special Equipment Inspection and Technique Research,Shanghai 200062,China;Jangsu Zhongtechuangye Equipment Inspection Co.,Ltd.,Jiangsu 225003,China;Chart Cryogenic Engineering Systems(Changzhou)Co.,Ltd.,Jiangsu 213125,China)

机构地区:[1]上海市特种设备监督检验技术研究院,上海200062 [2]江苏中特创业设备检测有限公司,南京225003 [3]查特深冷工程系统(常州)有限公司,常州213125

出  处:《无损检测》2020年第2期12-16,共5页Nondestructive Testing

摘  要:射线数字成像(DDA+CR)检测中,X射线管电压是最重要的工艺参数之一。目前,考虑到管电压过高会降低射线检测的主因对比度,国内外相关标准均对射线数字成像检测管电压的选用给出了相应的推荐值。试验对比DDA和CR检测时,缺陷试板在不同管电压下的数字图像质量和缺陷识别度,分析产生差别的原因,提出在合理范围内选用高于推荐值的管电压,配合相应的图像处理技术,可以提高数字图像信噪比,补偿由于管电压提高引起的图像对比灵敏度损失,最终提高缺陷识别度。试验结果表明:基于传统胶片照相工艺经验而来的管电压推荐值并不适用于射线数字成像检测,需根据特定的检测系统开展相关工艺试验确定X射线管电压上限值,且此上限值远高于相关标准的推荐值。X-ray voltage is one of the most important process parameters in digital radiography(DDA+CR).At present,domestic and foreign standards have given corresponding recommended values for the selection of the voltage during digital radiography,mainly considering that the higher tube voltage will reduce the primary contrast of the radiation detection.Comparison was made for the image quality and rate of defect recognition on changing Xray voltage in DDA and CR,and then the reasons of the differences were analyzed.It was proposed that a higher Xray voltage within reasonable limits and corresponding image processing technology could improve the signal-tonoise ratio of the digital image,and this would compensate for image sensitivity loss due to voltage increase,and ultimately improve the rate of defect recognition.The recommended value of the tube voltage based on the experience of the traditional film photographic process is not suitable for digital radiography.It is necessary to carry out relevant tests according to the specific detection system to determine the upper limit of the X-ray tube voltage,and the upper limit is much higher than recommended value by relevant standard.

关 键 词:射线数字成像检测 管电压 缺陷识别度 

分 类 号:TG156[金属学及工艺—热处理] TG115.28[金属学及工艺—金属学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象