某电厂省煤器管泄漏原因分析  被引量:1

Cause Analysis on Leakage of Economizer Tube in a Power Plant

在线阅读下载全文

作  者:李淑瑜 赵月 常青 张艳森 LI Shuyu;ZHAO Yue;CHANG Qing;ZHANG Yansen(Guodian Boiler and Pressure Vessel Inspection Co.,Ltd.,Beijing 102209,China)

机构地区:[1]国电锅炉压力容器检验有限公司,北京102209

出  处:《理化检验(物理分册)》2020年第3期29-31,共3页Physical Testing and Chemical Analysis(Part A:Physical Testing)

摘  要:某电厂省煤器管在第二次试运行期间发生泄漏。通过宏观检查、化学成分分析、金相检验、扫描电镜及能谱分析对省煤器管泄漏的原因进行了分析。结果表明:省煤器管存在制造缺陷,焊缝热影响区存在的魏氏组织和脱碳层使焊缝脆性增大,原始缺陷裂纹扩展直至造成省煤器管泄漏。Economizer tube of a power plant leaked during the second trial operation.The leakage cause of economizer tube were analyzed by macroscopic examination,chemical composition analysis, metallographic examination,scanning electron microscope and energy spectrum analysis.The results show that there were manufacturing defects in the economizer tube,widmanstatten structure and decarburization layer in the heat affected zone of the weld joint,which increased the brittleness of the weld joint,and the original crack defects expanded until the economizer tube leaked.

关 键 词:省煤器管 泄漏 制造缺陷 裂纹 

分 类 号:TM621.3[电气工程—电力系统及自动化]

 