一种高压击穿自动切换低压保持的放电管老化电路设计  

Design of Discharge Tube Aging Circuit with High Voltage Breakdown and Automatic Switching of Low Voltage Hold

在线阅读下载全文

作  者:李菁川 LI Jing-chuan(WuhanHuaTai Mechanical and Electrical Research Institution,School of Mechanical and Electrical,Wuhan Polytechnic,Wuhan 430074,China)

机构地区:[1]武汉职业技术学院机电工程学院华泰机械电子技术研究所,湖北武汉430074

出  处:《武汉职业技术学院学报》2020年第1期117-120,共4页Journal of Wuhan Polytechnic

摘  要:对放电管两端施加电压直至击穿后,再以规定电流保持一段时间的放电状态,是其出厂前必经的老化处理过程。不同型号的放电管有着不一样的击穿电压和放电电流,采用直接高压击穿后放电维持的传统方法需消耗较大的能量。为此设计应用了一种高压击穿后能自动切换为低压老化的电路,有效地解决了传统老化方法中电能消耗过大的问题。Applying voltage to both ends of the discharge tube until breakdown,and then maintaining the discharge state for a certain period of time with a specified current,is an aging process that must be performed before leaving the factory.Different types of discharge tubes have different breakdown voltages and discharge currents.The traditional method of maintaining discharge after direct high-voltage breakdown requires a large amount of energy.Therefore,a circuit that can automatically switch to low-voltage aging after high-voltage breakdown is designed and applied,which effectively solves the problem of excessive power consumption in traditional aging methods.

关 键 词:放电管的老化 高压击穿 低压老化 

分 类 号:TM862[电气工程—高电压与绝缘技术]

 