检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:高旸 GAO Yang(Tianjin Installation Engineering CO.,LTD,Tianjin 300202,China)
出 处:《青海大学学报》2020年第2期58-65,80,共9页Journal of Qinghai University
摘 要:为了实现多楼宇之间的集群化通讯控制,减少人工作业的强度。文中采用基于Modbus-RTU传统通讯方式,建立以楼宇为通讯单元和楼宇内多层集成化的新通讯模式。首先,实现被控楼宇内多层温控风机盘管的集中控制,然后实现多楼宇间群控功能。结果表明:新模式的使用比单层控制的传统通讯模式节约了遍历面板采集数据的时间。本研究对加快中国AI建筑的信息化转型以及进一步完善AI建筑集群化控制具有一定的参考价值。In order to achieve the cluster communication control among multiple buldings and to reduce the intensity of manual work,the traditional communication mode based on Modbus-RTU is adopted in this paper to establish a new multilevel integrated communication mode with buildings as communication units.Carrying out the centralized control of multi-storey temperature control fan coils in the controlled building,the group control function among multiple buildings is realized afterward.The results show that the new model traverses the data collected by the panel more efficiently than the traditional model of single-floor building control does.In fact,it is not only has a certain reference value for accelerating the information transformation of AI architectures in China but also further improves the AI building cluster control.
关 键 词:集群化通讯控制 数据采集 Modbus-RTU发送 Modbus-RTU接收 MODBUS协议
分 类 号:TP39[自动化与计算机技术—计算机应用技术] TN91[自动化与计算机技术—计算机科学与技术]