NG-240/9.8-M3型燃气锅炉定期排污系统改造  

Modification on Periodic Drainage System of NG-240/9.8-M3 Gas Boiler

在线阅读下载全文

作  者:金弘[1] 贾树勋 王庚 刘晓林 李猛 赵磊[1] JIN Hong;JIA Shu-xun;Wang Geng;LIU Xiao-lin;LI Meng;ZHAO Lei(Energy Source Management&Control Center of Angang Steel Co.,Ltd.,Anshan 114021)

机构地区:[1]鞍钢股份有限公司能源管控中心,鞍山114021

出  处:《冶金设备管理与维修》2020年第2期60-61,共2页Metallurgical Equipment Management and Maintenance

摘  要:NG-240/9.8-M3型锅炉原连续排污系统管路、弯管和三通泄漏频次高,采用扩容厚壁小联箱进行替换改造后,成功解决了连排系统泄漏频次高的问题.提升了锅炉的运行效率,达到节能降耗、安全检修、提升效益的目的.The original pipelines,bending pipes and three-way pipes of the drainage system of NG-240/9.8-M3 boiler often leak.After replacing with the capacity expanding thick-wall small header,the problem of high leakage rale is eliminated.The operation efficiency of the boiler is improved to achieve the goal of energy saving and consumption reduction,safe maintenance and benefits improving.

关 键 词:燃煤锅炉 泄漏 工艺改造 厚壁小联箱 