作 者:赵振峰[1] 王雪梅[1] 王瑞 白华军 祁迎春 Zhao Zhenfeng;Wang Xuemei;Wang Rui;Bai Huajun;Qi Yingchun(Department of Nuclear Medicine,the Affiliated Hospital of Inner Mongolia Medical University,Huhhot 010050,China;Department of Technical Services,Beijing Novel Medicine Equipment co.,LTD,Beijing 102206,China)
机构地区:[1]内蒙古医科大学附属医院核医学科,呼和浩特010050 [2]北京永新医疗设备有限公司技术服务部,102206
出 处:《国际放射医学核医学杂志》2020年第2期87-91,共5页International Journal of Radiation Medicine and Nuclear Medicine
基 金:内蒙古自治区科技重大专项课题(2017NMGKJZDZX)。
摘 要:目的研究北京永新医疗设备有限公司的NET632型SPECT与德国西门子公司的Symbia T16型SPECT/CT在全身骨骼显像中的等效性。方法选取2018年3月至9月于内蒙古医科大学附属医院行Symbia T16型SPECT/CT全身骨骼显像结果为阳性病灶的患者32例,其中男性21例、女性11例,年龄(60.87±12.25)岁。32例患者均使用NET632型SPECT行全身骨骼显像。将两种仪器的显像图像采用图像评分标准进行评分,比较阳性病灶累及区域和病灶数量。结果Symbia T16型SPECT/CT的图像质量评分为5分的患者有18例、4分的有14例,无3分及以下的患者;NET632型SPECT的图像质量评分为5分的患者有16例、4分的有16例,无3分及以下的患者。Symbia T16型SPECT/CT全身骨显像共发现阳性病灶累及区域数为84个,累及部位为胸部、脊柱、骨盆、四肢和颅骨,病灶数量分别为19、24、20、16、5个;NET632型SPECT在相同位置发现与其数目相等的病灶。结论永新医疗的NET632型SPECT与西门子公司的Symbia T16型SPECT/CT在全身骨骼显像探测病灶方面具有等效性。Objective To study the equivalence of the Novel Medical NET632 SPECT and the SIEMENS Symbia T16 SPECT/CT in whole-body bone scintigraphy.Methods A total of 32 cases(21 males and 11 females;aged 60.87±12.25 years)in the Department of Nuclear Medicine of the Affiliated Hospital of Inner Mongolia Medical University from March 2018 to September 2018 were found positive with bone lesions in the whole-body bone scintigraphy using the SIEMENS Symbia T16 SPECT/CT and the Novel Medical NET632 SPECT.Then,the image quality was compared using the same image scoring criteria.The positive lesion involvement area and the number of areas in each patient were determined using the two devices.Results The image qualities were scored 5,4,and 3(including<3)for 18,14,and 0 in the Symbia T16 SPECT/CT,and the image qualities were scored 5,4,and 3(including<3)for 16,16,and 0.A total of 84 positive lesion sites were found in the chest,spine,pelvis,limbs,and skull by using the Symbia T16 SPECT/CT,and the numbers in each location were 19,24,20,16,and 5,respectively.The same number of positive lesions was observed in the same locations for the NET 632 SPECT.Conclusion The Novel Medical NET632 SPECT and the SIEMENS Symbia T16 SPECT/CT detect the lesions in whole-body bone scintigraphy equivalently.
关 键 词:单光子发射计算机体层摄像术 体层摄影术 发射型计算机 单光子 全身骨骼显像 西门子Symbia T16型 永新医疗NET632型
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.112