探讨AI用于食管癌危及器官自动勾画的可行性  被引量:8

Feasibility of automatic delineation of OAR in radiotherapy of esophageal cancer utilizing AI

在线阅读下载全文

作  者:王萍[1] 王继平[1] 李鑫 陈传喜[1] 马晋茗 杨志勇[1] WANG Ping;WANG Jiping;LI Xin;CHEN Chuanxi;MA Jinming;YANG Zhiyong(Oncology Centre,Huanggang Central Hospital,Huanggang 438000 China;Department of Radiation Oncology,The Second People's Hospital of Yichang;Radiation Oncology Physics Technical Center,West China Hospital of Sichuan University)

机构地区:[1]湖北省黄冈市中心医院肿瘤中心,湖北黄冈438000 [2]湖北省宜昌市第二人民医院肿瘤放射治疗科 [3]四川大学华西医院肿瘤放射物理技术中心

出  处:《中国辐射卫生》2019年第6期709-713,共5页Chinese Journal of Radiological Health

摘  要:目的探讨人工智能用于食管癌危及器官自动勾画的几何学和剂量学精度。方法首先,选择100例食管癌患者基于连心人工智能平台建立图像数据库,每个患者包含5个已经手工勾画的危及器官。然后将其他20例患者CT图像传入人工智能平台,系统自动勾画危及器官作为目标图像,与手工勾画的危及器官进行几何学和剂量学比较。最后,分别比较两种勾画方式所需的时间、体积差异、重合度指标、相似性系数和剂量学差异。结果自动勾画比手工勾画左肺、右肺、心脏、肝脏和脊髓分别节省时间98.83%、94.55%、84.9%、77.96%和94.15%,两者差异有统计学意义(t=2.27、3.28、4.92、-1.39、0.21,P<0.05)。左肺、右肺、心脏、肝脏和脊髓体积差异分别为(5.58±2.53)cm3、(8.57±4.36)cm3、(0.97±0.34)cm3、(1.47±0.65)cm3和(0.73±0.21)cm3,DSC值为0.78~0.96,DSC>0.7,OR值为0.84~0.97,重合度好。自动勾画与手工勾画危及器官剂量学对比中,各项剂量学指标均符合临床要求,除右肺V5的剂量学指标的差异有统计学意义(t=0.41,P=0.04<0.05),左肺,右肺,肝脏,心脏和脊髓的其他剂量学指标的差异均无统计学意义(t=-1.23~3.11,P>0.05)。结论食管癌危及器官的自动勾画几何精度高,剂量学差异小,时间短。AI在临床中的应用,可以大大提升医师的工作效率。Objective To explore the geometric and dosimetric accuracy of automatic delineation of OAR in radiotherapy of esophageal cancer based on Artificial intelligence(AI).Methods Firstly,one hundred cases of esophageal cancer were selected to establish an image database based on the AI of LINKING MED.Each patient included five OARs that manually delineated.Then,the CT images of the other twenty patients were transferred to the AI,and the system automatically sketched the OARs as the target image,which could compare the geometry and dosimetry with the manually sketched OARs.Finally,the time,volume difference,overlap ratio(OR),dice similarity coefficient(DSC)and dosimetric difference of the two methods were compared respectively.Results Compared with manually sketching,the autosegmention saving time by 98.83%,94.55%,84.9%,77.96%and 94.15%in the left lung,right lung,heart,liver and spinal cord respectively,which were significant differences between the two groups(t=2.27,3.28,4.92,-1.39,0.21,P<0.05).The volume differences of left lung,right lung,heart,liver and spinal cord were(5.58±2.53)cm3,(8.57±4.36)cm3,(0.97±0.34)cm3,(1.47±0.65)cm3 and(0.73±0.21)cm3,DSC values were 0.78~0.96,DSC>0.7,and the OR values were 0.84~0.97,which had a good coincidence.In the comparison of dosimetry between autosegmention and manual,all the dosimetric indexes met the clinical requirements.Except for right lung in V5,which had significant difference in dosimetric indicators(t=0.41,P=0.04<0.05).There was no significant difference in other dosimetric indicators of left lung,right lung,liver,heart and spinal cord(t=-1.23~3.11,P>0.05).Conclusion The automatic delineation of OAR in esophageal cancer has suggests high geometric accuracy,small dosimetric difference and reduced time.The application of AI in clinical practice might greatly improve the work efficiency of doctors.

关 键 词:人工智能 自动勾画 危及器官 相似性系数 剂量学差异 

分 类 号:R815[医药卫生—放射医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象