臭氧发生器放电管故障诊断的研究  被引量:1

Study on fault diagnosis of discharge tube of ozone generator

在线阅读下载全文

作  者:丛培坤 刘钟阳[1] Cong Peikun;Liu Zhongyang(School of Electrical Engineering,Dalian University of Technology,Dalian 116024,Liaoning,China)

机构地区:[1]大连理工大学电气工程学院,辽宁大连116024

出  处:《电测与仪表》2020年第9期117-120,152,共5页Electrical Measurement & Instrumentation

摘  要:文中提出利用电磁感应原理,设计电磁线圈感应出电压,驱动LED发光管发光,观察发光管的亮暗即可判断放电管故障与否并且显示出哪根管故障,为检修提供指示功能。从理论与实验验证可行性,并以此设计出可靠的臭氧发生器放电管故障诊断系统。The principle of electromagnetic induction is proposed in this paper to design the electromagnetic coil to induce voltage,drive the LED luminescent tube to emit light,observe the brightness of the luminescent tube that can be judged whether the discharge tube fault or not,and show the fault of the tube,so as to provide the indicating function for maintenance.The feasibility is verified by theory and experiment,and a reliable fault diagnosis system for discharge tube of ozone generator is designed.

关 键 词:电磁感应 放电管故障 LED发光管 