应急照明设计中应注意的问题分析  被引量:3

Analysis of Problems that Should be Paid Attention in Emergency Lighting Design

在线阅读下载全文

作  者:梁志超 Liang Zhichao(Hunan Architectural Design Institute Co.,Ltd.,Changsha 410012,China)

机构地区:[1]湖南省建筑设计院有限公司,长沙410012

出  处:《智能建筑电气技术》2020年第2期22-25,共4页Electrical Technology of Intelligent Buildings

摘  要:GB 51309-2018《消防应急照明和疏散指示系统技术标准》于2019年3月1日正式实施以来,通过对新技术标准的学习与工程实践,其主要设计理念已在广大电气设计师具体的工程实践中得到了比较好的贯彻与落实。但设计工作中,对一些细节问题还是存在理解偏差,需要引起重视和注意。文中就目前设计应该引起设计师注意的几个问题进行了分析,以引起设计师重视和注意。After the formal implementation of the<Technical standard for tire emergency lighting and evacuate indicating system〉GB51309-2018 on March 1,2019,the main design concept of the technical standard of the new technical standard has been in the concrete engineering practice of the general electric designer.And the implementation and the implementation of the comparison are achieved.However,there are some details in the design work that need to be paid attention and attention.In this paper,some problems that should be noticed by the designer in the current design are analyzed,and the designer is reminded to pay attention to and pay attention to.

关 键 词:集中控制 应急照明 蓄电池 方向标志 最低照度 

分 类 号:TU892[建筑科学]

 