LBTF3200型篦冷机技术改造  

Technical Reform of LBTF3200 Grate Cooler

在线阅读下载全文

作  者:邹波 兰东 孙泽玖 林廷全 ZOU Bo;LAN Dong;SUN Zejiu;LIN Tingquan(Sichuan Xingchuancheng Cement Co.,Ltd.,Neijiang Sichuan 641000,China)

机构地区:[1]四川省星船城水泥股份有限公司,四川内江641000

出  处:《水泥技术》2020年第3期82-87,共6页Cement Technology

摘  要:介绍了LBTF 3200型篦冷机运行过程中存在的二次风温低、出篦冷机熟料温度高、热交换效率不理想等问题,分析了料层、冷却风机风压、风量对篦冷机性能的影响并提出了技术改造方案。技改后,二次风温平均提高40℃,三次风温平均提高68℃,窑头喂煤量平均减少0.5t/h,分解炉喂煤量平均减少0.2t/h,年节煤资金可达上百万元。This paper introduces the problems of low secondary air temperature,high clinker temperature and unsatisfactory heat exchange efficiency in the operation of LBTF 3200 grate cooler,analyzes the influence of material layer,air pressure of cooling fans and air volume on the performance of grate cooler,and puts forward the technical reform plan.After the technical reform,the secondary air temperature increases by 40℃on average,the third air temperature increases by 68℃on average,the coal feeding quantity of kiln head decreases by 0.5 t/h on average,the coal feeding quantity of decomposition furnace decreases by 0.2 t/h on average,and the annual coal saving fund can reach millions of yuan.

关 键 词:篦冷机 料层 冷却风机 喂料量 改造 

分 类 号:TQ172.622.4[化学工程—水泥工业]

 