影像科对比剂外渗的原因分析及护理对策  被引量:1

Analysis of causes of contrast media leakage in imaging department and nursing countermeasures

在线阅读下载全文

作  者:周平 连贵君 杜燕秀 邓利梅 Zhou Ping;Lian Guijun;Du Yanxiu;Deng Limei(Southwest Medical University Affiliated Hospital Radiology Department,Sichuan,Luzhou 646000,China)

机构地区:[1]西南医科大学附属医院放射科,四川泸州646000

出  处:《影像研究与医学应用》2020年第11期29-31,共3页Journal of Imaging Research and Medical Applications

摘  要:目的:探究影像科对比剂外渗的原因分析及护理对策。方法:研究对象选取我院2019年1月—2020年2月接受影像科检查的200例患者,随机法平均分为对照组和实验组。对照组用常规护理,实验组用护理干预,比较组间患者护理质量。结果:对照组患者对比剂外渗发生率为58.00%,明显高于实验组的4.00%(P<0.01)。发生对比剂外渗与患者年龄、穿刺血管选取、全身性因素、护理人员操作不当、高团注速度等影响因子相关。结论:患者行影像科检查过程中实施护理干预,可有效降低对比剂外渗发生率,提升护理人员操作规范程度。Objective To explore the causes of contrast extravasation in imaging department and its nursing countermeasures.Methods 200 patients who received imaging examination in our hospital from January 2019 to February 2020 were randomly divided into control group and experimental group.Routine nursing was used in the control group,and nursing intervention was used in the experimental group.Results The incidence of contrast extravasation in the control group was 58.00%,significantly higher than that in the experimental group(4.00%)(P<0.01).The occurrence of contrast extravasation was related to age of patients,selection of puncture vessels,systemic factors,improper operation of nurses,high group injection speed and other factors.Conclusion Nursing intervention can effectively reduce the incidence of contrast agent extravasation and improve the operation standard of nurses.

关 键 词:影像科 对比剂外渗 原因分析 护理对策 

分 类 号:R473[医药卫生—护理学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象