不同流式细胞检测平台检测HIV病人CD4^+T淋巴细胞敏感性分析  被引量:1

Sensitivity analysis of different flow cytometry detection platforms for determination of CD4^+T lymphocyte of HIV infected patients

在线阅读下载全文

作  者:金涛[1] 胡晓远[1] 马媛媛[1] 王凤英[1] 倪明健[1] JIN Tao;HU Xiao-yuan;MA Yuan-yuan;WANG Feng-ying;NI Ming-jian(The Center for Disease Control and Prevention of Xinjiang Uygur Autonomous Region,Urumqi,Xinjiang 830002,China)

机构地区:[1]新疆维吾尔自治区疾病预防控制中心,乌鲁木齐830002

出  处:《疾病预防控制通报》2020年第2期15-17,22,共4页Bulletin of Disease Control & Prevention(China)

基  金:国家科技重大专项艾滋病和病毒性肝炎等重大传染病防治(2018ZX10715-007);新疆维吾尔自治区卫生计生委青年医学科技人才专项科研项目(WJWY-201859);新疆艾滋病防控研究重点实验室项目。

摘  要:目的对比不同机型不同检测试剂检测人体CD4^+T淋巴细胞数值,为建立快速、稳定且敏感性高的检测平台提供依据。方法对比BD的3个型号机器(Calibur,Count和Presto)及艾森ACEA NovoCyte流式细胞仪平行检测111份艾滋病感染者/病人(HIV/AIDS)血样中CD4+T淋巴细胞计数结果,以统计学软件评估检测结果的一致性和差异性;利用单平台对比不同试剂对CD4^+T淋巴细胞计数检测结果的影响。结果3种BD机型的CD4^+T淋巴细胞计数结果差异无统计学意义(Pearson r=0.962,0.977和0.978,P>0.05),但Presto检测步骤少、操作简单;在BD Calibur检测平台上,BD试剂和同生时代试剂检测结果的Pearson r=0.904,差异有统计学意义(P<0.05);在艾森平台上,不同试剂检测结果差异无统计学意义(Pearson r=0.983,0.975和0.970,P>0.05)。结论BD各型号机器对HIV/AIDS的CD4^+T淋巴细胞检测结果有高度的一致性,但对于国产试剂的兼容性不如艾森流式细胞仪。Objective To compare CD4^+T lymphocyte values of human body by combining different test reagents with different models,provide a basis for establishing a rapid,stable and sensitive test platform.Methods The results of CD4^+T lymphocyte count in the blood samples of 111 HIV infectors/AIDS patients(HIV/AIDS)were compared by three BD machines(Calibur,Count and Presto)and parallel detection(ACEA NovoCyte).The consistency and difference in the results were evaluated with statistical software.The effects of different reagents on CD4^+T lymphocyte count on a single platform were compared.Results There was no statistical difference in CD4^+T lymphocyte count results among the three BD models(Pearson correlation coefficients of 0.962,0.977 and 0.978,respectively,P>0.05).However,Presto detection was of few procedures and simple operation.The Pearson coefficient of BD reagent and syngenetic reagent on BD Calibur detection platform was 0.904,with statistical difference(P<0.05).On ACEA platform,there was no statistical difference in the detection results of different reagents(Pearson correlation coefficients of 0.983,0.975 and 0.970,P>0.05).Conclusions The detection results of CD4^+T lymphocyte of HIV/AIDS by BD machines are highly consistent,but the compatibility of domestic reagent is not as good as that of ACEA flow cytometry.

关 键 词:艾滋病 CD4^+T淋巴细胞 流式细胞仪 一致性 

分 类 号:R512.91[医药卫生—内科学]

 