检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:瓦武奎 黎兆锋 朱广见 杨春波 代荣招 WA Wu-kui;LI Zhao-feng;ZHU Guang-jian;YANG Chun-bo;DAI Rong-zhao(Yunnan Huadian Kunming Power Generation Co.,Ltd.,Kunming 650308,China)
机构地区:[1]云南华电昆明发电有限公司,云南昆明650308
出 处:《云南水力发电》2020年第3期163-165,共3页Yunnan Water Power
摘 要:云南华电昆明发电有限公司300MW机组为设计烟煤机组,为降低燃料成本,采取了全烧褐煤的措施,但随着全烧比例的提高,制粉系统故障、空预器堵塞、飞灰含碳量高、燃烧器喷口烧毁等问题严重影响锅炉安全,2018年5月,机组实现全烧褐煤。The 300MW unit of Yunnan Huadian Kunming Power Generation Co.,Ltd.is designed as a bituminous coal unit.In order to reduce the fuel cost,the measures of blending and burning lignite have been taken.However,with the increase of blending and burning ratio,the problems of pulverizing system failure,air preheater blockage,high carbon content of fly ash,burner nozzle burning and so on seriously affect the safety of the boiler.In May 2018,the unit realized the full burning of lignite.This paper describes the full burning of lignite Influence of lignite on boiler and countermeasures.
分 类 号:TM621.2[电气工程—电力系统及自动化]