检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:罗敬 张晓辉[1] 何煦[1] 叶露[1] 张天一 LUO Jing;ZHANG Xiao-hui;HE Xu;YE Lu;ZHANG Tian-yi(Changchun Institute of Optics,Fine Mechanics and Physics,Chinese Academy of Sciences,Changchun 130033,China)
机构地区:[1]中国科学院长春光学精密机械与物理研究所,吉林长春130033
出 处:《中国光学》2020年第3期558-567,共10页Chinese Optics
基 金:国家自然科学基金资助项目(No.61875190,No.61675198)。
摘 要:本文首次提出并构建了自准直仪光电探测器失调的数学模型。基于该模型,分析了光电探测器相对于理论像面处于空间任意位置和朝向时对自准直仪测角的影响。结果表明,探测器失调造成的测角误差随准直物镜焦距f的增大而减小,随自准直仪到被测镜面的距离L以及待测角度θ的增大而增大。计算发现,当f=300 mm,L=100 mm,θ=20″时,因探测器失调引起的测角误差达到0.0045″。文章进一步分析了各种探测器失调误差单独作用时对自准直仪测角的影响,验证了模型的正确性,并发现探测器离焦对自准直仪的影响最大。根据本文计算结果,选择长焦距的成像物镜、减小测量距离、提高光电探测器沿轴向的安装精度是减小光电探测器失调对自准直仪影响的关键。基于提出的数学模型,可以系统地计算探测器失调对自准直仪测角的影响,进而为构建更加完善的自准直仪误差模型奠定基础。As one of the key errors in autocollimators,misalignment of the photodetector is analyzed and modeled carefully in this paper.Effect of misalignment of the photodetector on angle measurements is characterized,when the photodetector in any position and orientation in space with respect to the theoretical im-age plane of autocollimators.It is shown that the angular measurement errors of autocollimators induced by a misaligned photodetector increase with greater measuring range L,larger angleθand smaller focal length f of the collimating object lens.When f=300 mm,L=100 mm,θ=20″,the angular measurement error caused by a misaligned photodetector is 0.0045″.The effects of each photodetector misalignment error on angle measurements in autocollimators are characterized.The model proposed in this paper is validated.Among all kinds of photodetector misalignment errors,the defocusing error has the greatest influences on autocollimators.Hence,it is critical to choose an imaging objective with longer focal length,reduce the measurement distance,and improve the installation accuracy of the photodetector along the axis.The model proposed in this paper helps to systematically obtain the angular measurement errors caused by a misaligned photodetector,which will play a key role in building a better error analysis model for autocollimators.
分 类 号:TP394.1[自动化与计算机技术—计算机应用技术] TH691.9[自动化与计算机技术—计算机科学与技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.30