检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Kang-Min Zhou Wei Miao Yue Geng Yan Delorme Wen Zhang (任远) Kun Zhang Sheng-Cai Shi 周康敏;缪巍;耿悦;Yan Delorme;张文;任远;张坤;史生才(Purple Mountain Observatory,Chinese Academy of Sciences,Nanjing 210023,China;Key Laboratory of Radio Astronomy,Chinese Academy of Sciences,Nanjing 210023,China;Observatoire de Paris,75014 Paris,France;University of Science and Technology of China,Hefei 230026,China)
机构地区:[1]Purple Mountain Observatory,Chinese Academy of Sciences,Nanjing 210023,China [2]Key Laboratory of Radio Astronomy,Chinese Academy of Sciences,Nanjing 210023,China [3]Observatoire de Paris,75014 Paris,France [4]University of Science and Technology of China,Hefei 230026,China
出 处:《Chinese Physics B》2020年第5期41-46,共6页中国物理B(英文版)
基 金:Project supported by the Chinese Academy of Sciences(Grant Nos.GJJSTD20180003 and QYZDJ-SSW-SLH043);the National Key Basic Research and Development Program of China(Grant Nos.2017YFA0304003 and 2018YFA0404701);the National Natural Science Foundation of China(Grant Nos.11603081,11673073,U1831202,and 11873099);PICS projects between the CAS and the CNRS.
摘 要:We report on the investigation of optimal bias region of a wide-band superconducting hot electron bolometer(HEB)mixer in terms of noise temperature performance for multi-pixel heterodyne receiver application in the 5-meter Dome A Terahertz Explorer(DATE5)telescope.By evaluating the double sideband(DSB)receiver noise temperature(Trec)across a wide frequency range from 0.2 THz to 1.34 THz and with a large number of bias points,a broad optimal bias region has been observed,illustrating a good bias applicability for multipixel application since the performance of the HEB mixer is uniquely determined by each bias point.The noise temperature of the HEB mixer has been analyzed by calibrating the noise contribution of all RF components,whose transmissions have been measured by a time-domain spectroscopy.The corrected noise temperature distribution shows a frequency independence relation.The dependence of the optimal bias region on the bath temperature of the HEB mixer has also been investigated,the bath temperature has limited effect on the lowest receiver noise temperature until 7 K,however the optimal bias region deteriorates obviously with increasing bath temperature.
关 键 词:superconducting hot electron bolometer(HEB)mixer noise temperature distribution bath temperature dependence frequency dependence
分 类 号:TN773[电子电信—电路与系统] TH811[机械工程—仪器科学与技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.148