计及N-1准则的含光伏发电系统运行风险的评估  

Considering N-1 of Photovoltaic Power Generation Systems Run the Risk Assessment Criteria

在线阅读下载全文

作  者:李从飞 LI Cong-fei(Nanjing Hongyi Electric Automation Co.,Ltd,Nanjing 210039,China)

机构地区:[1]南京弘毅电气自动化有限公司,江苏南京210039

出  处:《电工电气》2020年第6期29-33,共5页Electrotechnics Electric

摘  要:为了研究光伏接入对系统运行风险的影响,介绍了基于非参数核密度估计建立光伏电站出力概率模型的方法,在此基础上引入Well-being框架,提出了考虑N-1安全准则的含光伏发电的系统运行风险评估算法。以IEEE RTS系统为例进行了算例分析,算例结果证明了基于非参数核密度估计建立光伏不确定性模型和所提出的考虑N-1安全准则的系统风险评估算法的正确性。In order to study the impact of photovoltaic access on system operation risk,this paper introduces the method of establishing the probabilistic model of photovoltaic power plant output based on non-parametric kernel density estimation.On this basis,the Well-being framework is introduced,and the operational risk assessment algorithm of the photovoltaic power generation system considering N-1 safety criteria is proposed.Taking the IEEE RTS system as an example,a case analysis is carried out.The results of the example prove the correct-ness of the system risk assessment algorithm based on the non-parametric kernel density estimation to establish the photovoltaic uncertainty model and the proposed N-1 safety criterion.

关 键 词:光伏发电系统 非参数核密度估计 N-1准则 Well-being框架 运行风险 

分 类 号:TM615[电气工程—电力系统及自动化] TM715

 