浅谈兴济地震台地电场电极更换的经验  

Discussion on the Experience of Changing the Geoelectric Field Electrode in Xingji Seismic Station

在线阅读下载全文

作  者:李瑞卿[1] 郭学增[1] 张蕾[1] 信世民 张国苓[2] LI Rui-qing;GUO Xue-zeng;ZHANG Lei;XIN Shi-min;ZHANG Guo-ling(Xingji Seismic Station, Hebei Earthquake Agency, Cangzhou, Hebei 061721, China;Hebei Earthquake Agency, Shijiazhuang, Hebei 050021, China)

机构地区:[1]河北省地震局兴济地震台,河北沧州061721 [2]河北省地震局,河北石家庄050021

出  处:《山西地震》2020年第2期44-47,共4页Earthquake Research in Shanxi

摘  要:通过对近几年兴济地震台地电场电极故障判断及更换工作进行总结,得出通过数据图像同步变化特征判断电极故障的方法;在更换电极时,较好的更换方法可以增强电极使用性能,延长电极使用寿命。如,使用洛阳铲挖取电极坑,减少对原土层的破坏;埋设电极尽量在潜水层水面以下,保障电极使用环境稳定;电极埋设后等一周时间,待电极稳定后再接入观测等。该经验总结可为及时判断电极故障以及优化电极更换方法提供借鉴参考。Based on the summary of the geoelectric field electrode fault judgment and replacement work of Xingji seismic station in recent years,the method to judge the electrode fault through the synchronous change characteristics of data image is obtained.When replacing the electrode,the better replacement method can increase the electrode performance and prolong the electrode service life.For example,the Luoyang shovel can be used to dig the electrode pit to reduce the damage to the original soil layer;the electrode should be buried as far as possible below the water surface of the phreatic layer to ensure the stable use environment of the electrode;after the electrode is buried,a week should be waited for the electrode to be stable before the observation.The experience can be used for reference in judging electrode fault and optimizing electrode replacement methods.

关 键 词:地电场 电极 故障判断 

分 类 号:P319.19[天文地球—固体地球物理学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象