检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张伟 饶宇[2,3] 刘美山[2] 卞文龙 王贤武 段俊涛 刘志芳 ZHANG Wei;RAO Yu;LIU Meishan;BIAN Wenlong;WANG Xianwu;DUAN Juntao;LIU Zhifang(Shengli Branch,Petroleum Engineering Geophysical Limited Corporation,SINOPEC,Dongying 257000,China;Key Laboratory of Geotechnical Mechanics and Engineering of Ministry of Water Resources,Yangtze River Scientific Research Institute,Wuhan 430010,China;School of Civil Engineering and Architecture,Wuhan University of Technology,Wuhan 430070,China;Qinghai Materials Industry Blasting Technology Service Limited Corporation,Xining 810000,China)
机构地区:[1]中石化石油工程地球物理公司胜利分公司,山东东营257000 [2]长江科学院水利部岩土力学与工程重点实验室,湖北武汉430010 [3]武汉理工大学土木工程与建筑学院,湖北武汉430070 [4]青海物产爆破技术服务有限公司,青海西宁810000
出 处:《人民长江》2020年第5期119-124,共6页Yangtze River
基 金:国家自然科学基金青年科学基金项目(51609017)。
摘 要:地震勘探作业中众多保护物的安全控制标准并无规范可依,因此通过多种方法的分析和相互验证确定合理的振动安全控制标准尤为重要。以山东省胜利油田东部探区为例,首先基于应力波和破坏准则的理论对各类保护物的强度进行验算,然后考虑爆破振动对人居环境的影响和各类保护对象抗震设防要求,并采用现有规范进行校验,最后选取4种方法中的最小值作为胜利油田东部探区不同保护对象的地震勘探振动安全控制标准。研究结果表明:强度验算确定的控制标准值一般比抗震设防和规范控制标准宽松得多,抗震设防和规范要求具有较大的安全富余,瑞利波传播速度理论上为横波传播速度的0.87~0.95倍;对于地表建筑物,应采用面波进行受力分析,对传播介质内部建筑物应采用体波进行强度验算。Standards for safety control of many protective objects in seismic exploration operations have no guides.Therefore,it is important to determine a reasonable vibration safety control standard through analysis and mutual verification of various methods.Firstly,based on the theory of stress wave and damage criterion,the strength of various protective objects in east exploration area of Shengli Oilfield was checked.Then the impact of blasting vibration on the human settlement sites and the seismic protection requirements of various protected objects were analyzed,and the existing specifications were used to verify the previous checking results.Finally,the minimum values calculated by four different checking methods were used as the seismic safety control standard for protection objects.The research results show that the control standard values determined by the strength check calculation are generally less strict than the anti-seismic codes,and the requirements in anti-seismic codes have greater safety margins.The Rayleigh wave propagation velocity is theoretically 0.87 to 0.95 times of the shear wave propagation velocity.For the surface buildings,surface waves should be used for stress analysis,and for buildings inside the propagation medium,body waves should be used for strength checking.
关 键 词:地震勘探 爆破振动 安全控制标准 强度验算 胜利油田
分 类 号:P631[天文地球—地质矿产勘探]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222