检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:邵琳 杨金溢 李志涌 蔡永壮 吴则琪 SHAO Lin;YANG Jinyi;LI Zhiyong;CAI Yongzhuang;WU Zeqi(College of Building Environment Engineering,Zhengzhou University of Light Industry,Zhengzhou Henan 450002,China)
机构地区:[1]郑州轻工业大学建筑环境工程学院,河南郑州450002
出 处:《安全》2020年第6期59-62,共4页Safety & Security
基 金:河南省科技攻关计划(192102310252);郑州轻工业大学博士科研基金。
摘 要:为了研究狭长空间防火挡烟设施的效果,通过数值模拟方法,研究了狭长空间中两挡烟垂壁间距对烟气阻滞作用的影响规律。研究结果发现,烟气越过前挡烟垂壁后,根据烟气流动状态可分为3个流动区域,即涡旋区、涌波区和定常流动区。当后挡烟垂壁位于涌波区,挡烟垂壁间距3~6m时,阻烟效果最佳。In order to study the effect of fire and smoke prevention facilities in long-narrow spaces,the influence regulations of the space between two smoke barriers on the smoke retardation effect in a long-narrow space were studied.The results showed that too large or too small the space between the smoke barriers would reduce the smoke retardation effect.After analysis of the smoke velocity vector diagram,it was found that the smoke after the front barrier could be divided into three flow areas according to the flow state,namely the vortex area,surge area and steady flow area.The smoke retardation effect is best when the rear smoke barrier is located in the surge zone.The simulation results of the used model show that the best smoke blocking effect is when the smoke barrier space is 3~6m.At this time,the rear smoke barrier is located in the surge area,confirming the analysis result of the smoke velocity vector diagram.
关 键 词:火灾烟气 狭长空间 挡烟垂壁 最优间距 阻滞作用
分 类 号:X932[环境科学与工程—安全科学]