检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:姚龙燕 丘伟兰 袁间梅 YAO Long-yan;QIU Wei-lan;YUAN Jian-mei
机构地区:[1]广东医科大学顺德妇女儿童医院(佛山市顺德区妇幼保健院),佛山市528300
出 处:《护理实践与研究》2020年第12期25-27,共3页Nursing Practice and Research
摘 要:目的探讨新生儿经外周静脉置入中心静脉导管(PICC)相关并发症发生危险因素及护理对策。方法选取2019年2—10月就诊于我院的PICC置管新生儿128例,其中发生PICC导管并发症32例。统计PICC导管并发症类型,采用单因素和多因素logistic回归分析新生儿PICC导管相关并发症发生的危险因素。结果32例新生儿PICC导管相关并发症中,导管堵塞占比最高,其次为机械性静脉炎、导管异位、导管相关血流感染、导管断裂。经单因素分析,出生体质量<1500 g、外部未加固、导管尖端未到达预期位置、留置时间>15 d、连续输液是新生儿PICC导管相关并发症发生因素(P<0.05)。多因素logistic回归分析显示,出生体质量<1500 g、外部未加固、导管尖端未到达预期位置、留置时间>15 d、连续输液是新生儿PICC导管相关并发症发生的独立危险因素(P<0.05)。结论出生体质量<1500 g、外部未加固、导管尖端未到达预期位置、留置时间>15 d、连续输液是新生儿PICC导管相关并发症发生危险因素,需采用针对性护理干预措施,降低PICC导管相关并发症发生率。Objective To explore the risk factors and nursing countermeasures of related complications in neonates with peripherally inserted central venous catheters(PICC)catheter.Methods To select 128 cases of neonates with PICC catheters who were admitted to our hospital from February to October 2019,among them,32 cases of patients had PICC catheter complications.The types of PICC catheter complications were counted,and univariate and multi-factor logistic regression were used to analyze the risk factors of neonatal PICC catheter-related complications.Results Among the 32 neonates with PICC catheter-related complications,catheter occlusion accounted for the highest proportion,followed by mechanical phlebitis,catheter ectopic,catheter-related bloodstream infection,and catheter was rupture.Univariate analysis showed that the birth weight<1500 g,unreinforced external,catheter tip did not reach the expected position,indwelling time>15 d,continuous infusion were the factors in neonates with PICC catheter related complications(P<0.05).Multivariate logistic regression analysis showed that the birth weight<1500 g,unreinforced external,catheter tip did not reach the expected position,indwelling time>15 d,continuous infusion were the independent risk factors in neonates with PICC catheter related complications(P<0.05).Conclusion The birth weight<1500 g,unreinforced external,catheter tip did not reach the expected position,indwelling time>15 d,continuous infusion were the risk factors in neonates with PICC catheter related complications.The targeted nursing interventions were needed to reduce the incidence rate of PICC catheter-related complications.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.147