350MW超临界四角切圆锅炉汽温偏差偏低燃烧调整与运行优化  被引量:2

Combustion Adjustment and Operation Optimization of 350MW Supercritical Tangential Firing Boiler with Low and Unbalanced Steam Temperature

在线阅读下载全文

作  者:荣俊 袁东辉[1] 蔡斌[1] 王研凯[1] 韩义[1] 于英利[1] 杨光 RONG Jun;YUAN Dong-hui;CAI Bin(Inner Mongolia Electric Power Research Institute)

机构地区:[1]内蒙古电力科学研究院,内蒙古呼和浩特010000

出  处:《电站系统工程》2020年第4期33-36,共4页Power System Engineering

摘  要:某电厂350 MW超临界四角切圆锅炉,长期掺烧劣质煤种和煤泥,燃用煤种严重偏离设计煤种,导致分隔屏过热器右侧汽温较左侧汽温长期偏高20~60℃和末级过热器出口蒸汽温度较设计值偏低10~30℃两个突出问题。分析问题产生的主要原因,并进行针对性的燃烧调整和运行优化,经过优化调整后,在260MW摸底工况下,分隔屏过热器出口汽温偏差控制在10℃左右,末级过热器出口蒸汽温度提高15.81℃,较设计参数低5.69℃。A 350MW supercritical quadrangled and tangential firing boiler,due to long-term mixing and burning of inferior coal and slime,the fired coal was seriously deviated from the designed coal,resulting in two prominent problems:the right side steam temperature of separator superheater is higher 20℃~60℃than the left side,the outlet steam temperature of the final superheater is 10℃~30℃lower than the designed value.The main causes of the problem is analyzed then carries out targeted combustion adjustment and operation optimization.After optimization and adjustment,under the working condition of 260MW,the steam temperature deviation at the outlet of the separator superheater was controlled at about 10℃,and the steam temperature at the outlet of the final superheater was increased by 15.81℃,5.69℃lower than the design parameters.

关 键 词:350 MW超临界锅炉 四角切圆 汽温偏差 燃烧优化 