多离子计数器动态多接收方式锆石Pb同位素比值高精度测定方法  被引量:1

High-Precision Pb Isotope Ratio Determination of Zircon By Multi-Ion CounterTIMS with Multi-Dynamic Collection Method

在线阅读下载全文

作  者:王伟[1,2,3] 储著银 李潮峰[1,3] 刘文贵[4] 许俊杰 郭敬辉[1,3] Wang Wei;Chu Zhuyin;Li Chaofeng;Liu Wengui;Xu Junjie;Guo Jinghui(State Key Laboratory of Lithospheric Evolution,Institute of Geology and Geophysics,Chinese Academy of Sciences,Beijing 100029,China;University of Chinese Academy of Sciences,Beijing 100049,China;Innovation Academy for Earth Science,Chinese Academy of Sciences,Beijing 100029,China;State Key Laboratory of Geological Processes and Mineral Resources,China University of Geosciences,Wuhan 430074,China;School of Ocean Sciences,China University of Geosciences,Beijing 100083,China)

机构地区:[1]中国科学院地质与地球物理研究所岩石圈演化国家重点实验室,北京100029 [2]中国科学院大学,北京100049 [3]中国科学院地球科学研究院,北京100029 [4]中国地质大学地质过程与矿产资源国家重点实验室,湖北武汉430074 [5]中国地质大学海洋学院,北京100083

出  处:《地球科学》2020年第6期1977-1985,共9页Earth Science

基  金:国家自然科学基金项目(No.41673061);中国科学院仪器设备功能开发项目(No.IGG201803)。

摘  要:采用装配多离子计数器系统的TRITON Plus热电离质谱仪(thermal ionization mass spectrometer,TIMS),建立了多离子计数器动态多接收锆石Pb同位素(以205Pb为稀释剂)测定方法 .相对多离子计数器静态多接收方法,该方法完全消除了不同离子计数器间增益差异对锆石Pb同位素测定的影响.相对传统的单个二次电子倍增器(secondary electron multiplier,SEM)五次跳峰的锆石Pb同位素测定方法,该方法两次跳峰即可测定全部Pb同位素比值,Pb同位素离子流接收效率提高2.5倍,同时,降低了离子流稳定性对Pb同位素分析结果的影响.为验证方法的可靠性,对加入205Pb稀释剂的NIST981 Pb标准和标准锆石清湖(Qinghu)进行了测定.对5×10-11g205Pb-NIST981 Pb混标,207Pb/206Pb测定精度达到0.079%(2RSD,n=20);对清湖标准锆石,获得的年龄结果为159.51±0.11 Ma(2SE,n=7;MSWD=1.1),与文献报道值在误差范围内一致.A high precision zircon Pb isotope ratio measurement method(using205 Pb as spike) was developed with a TRITON Plus thermal ionization mass spectrometer(TIMS) equipped with a multiple ion-counting(MIC) system. With the method, the Pb isotopes were measured with multi-ion counters using a multi-dynamic ion collection method. Compared to the traditional static multi-collection MIC method, the multi-dynamic MIC method can completely eliminate the influence of gain bias between different ion counters on the Pb isotope analytical results. Compared to the traditional zircon ID-TIMS Pb isotopic measurement method using a single secondary electron multiplier(SEM) with five peak jumps, the multi-dynamic MIC method can determine all the Pb isotope ratios of zircon in two peak jumps. Thus, the ion collection efficiency for the Pb isotopes were improved by 2.5 folds. In the meantime, the influences of ion beam stability on the analytical results of Pb isotopes was also reduced. To verify the reliability of the method, NIST981 Pb standards doped with205 Pb spike and Qinghu standard zircons were measured. The analytical precision of 207 Pb/206 Pb for 5×10-11 g of205 Pb-NIST981 Pb mixture can achieve 0.079%(2 RSD, n=20). The analytical206 Pb/238 U age result for Qinghu standard zircon was 159.51±0.11 Ma(2 SE, n=7;MSWD=1.1), which was consistent with the previously reported values within analytical error.

关 键 词:同位素稀释-热电离质谱法 多离子计数器 锆石 Pb同位素分析 205Pb稀释剂 地球化学 

分 类 号:P597.3[天文地球—地球化学]

 