检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李红梅 曹益平(指导)[1] 王亚品[1] 王璐 李城梦 安海华 徐财 Li Hongmei;Cao Yiping;Wang Yapin;Wang Lu;Li Chengmeng;An Haihua;Xu Cai(College of Electronics and Information Engineering,Sichuan University,Chengdu 610064,China;College of Physics and Engineering,Chengdu Normal University,Chengdu 611130,China)
机构地区:[1]四川大学电子信息学院,四川成都610064 [2]成都师范学院物理与工程技术学院,四川成都611130
出 处:《红外与激光工程》2020年第6期84-91,共8页Infrared and Laser Engineering
基 金:国家高技术研究发展计划(863计划)(2007AA01Z333);国家科技重大专项(2009ZX02204-008)。
摘 要:提出了一种基于灰度拓展的单帧正交复合光栅三维测量方法。由于受商用DLP最大灰阶动态范围256的标准限制,单帧复合光栅中的多张调制光栅共享256灰阶动态范围导致其对比度变小,其表征的三维物体的相位信息被压缩,解相过程出现相位断裂现象,测量误差增大。采用时分复用原理,将一具有766灰阶的正交复合光栅拆分为三幅不同的具有256灰阶的条纹图。依次序加载进循环播放的视频中投射至待测物体表面,当用曝光时间为3倍视频刷新周期的整数倍10 bit CCD采集时,就可采集到具有766灰阶动态范围的变形复合光栅像。通过滤波和灰度校准等计算后,物体的三维面形能够完整而精确的重建。经仿真和实验验证,所提方法打破了DLP256灰度投影的限制,有效提高了相移变形条纹的动态范围,增大了被测物体细节信息,避免了相位展开环节相位断裂而引起物体面形重构不完整的现象。A single-shot 3D shape measurement using orthogonal composited grating based on grayscale expanding(OCGGE)was proposed.In the traditional orthogonal composited grating(OCG)profilometry,the modulated gratings in the orthogonal composited grating must share the same grayscale level since the maximal grayscale dynamic range of commercial Digital Light Processing(DLP)is limited in 256,that results in some phenomenon increasing the measuring error,including the weakened contrast of the modulated grating,the compressed phase information and the broken phase during the process of phase unwrapping.Based on the principle of time division multiplexing,one orthogonal composited grating was designed with 766 gray level and was spited into three different fringe patterns with 256 grayscales,then loaded these patterns in sequence to edit a video.When this video was played and projected onto the measured object continuously,by setting the exposure time as an integer times of the 3 times of the frame refresh cycle of the video for a 10 bit CCD,a deformed pattern with 766 grayscales could be obtained.After the filtering and grayscale calibration,the object could be reconstructed accurately and completely.Both simulation and experiment results prove that the proposed method can break the limit of 256 grayscale projection and increase the dynamic range of the phase-shifting deformed patterns efficiently.And it can also enrich the detailed information of the measured object and avoid the incomplete surface reconstruction caused by phase break.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.12.198.162