检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王建[1] 翁正瀚 顾德文[3] 厍海波 艾三 杜志叶[1] WANG Jian;WENG Zhenghan;GU Dewen;SHE Haibo;AI San;DU Zhiye(School of Electrical Engineering,Wuhan University,Wuhan 430072,China;Jingmen Power Company of State Grid,Jingmen 44800,China;Central China Grid Company Limited,Wuhan 430000,China;Jinguan Electric Co.,Ltd.,Nanyang 473000,China)
机构地区:[1]武汉大学电气工程学院,武汉430072 [2]国网荆门供电公司,湖北荆门448000 [3]华中电网有限公司,武汉430000 [4]南阳金冠电气有限公司,河南南阳473000
出 处:《电瓷避雷器》2020年第3期133-139,共7页Insulators and Surge Arresters
摘 要:阻容网络理论根据避雷器实际结构和具体的设备配置建模,对避雷器传统的三相单节对称相间干扰分析模型作出了较大改进,但未总结具体建模的合理性。基于避雷器阻容网络理论,选择500 kV智能变电站三相避雷器系统建立3种阻容网络进行仿真分析。总结阻容网络仿真结果与所选择模型(导体数量)的变化规律,与监测数据结合,讨论阻容网络建模合理性。结果表明,典型500 kV智能变电站三相避雷器系统的阻容网络,避雷器需分节,需考虑相邻电压互感器及上端水平母线等影响,仿真结果才能与现场监测数据有更好的一致性。进而根据最合理的阻容网络模型对监测数据进行分析计算,诊断避雷器状态。On the basis of the actual structure of the lightning arrester and the specific equipment configuration,the theory of the resistance capacitance network has made a great improvement on the traditional three-phase single node symmetric Interphase Interference Analysis Model of the lightning arrester,but it does not sum up the rationality of the concrete modeling.Based on the theory of arrester resistance capacity network,this paper chooses three phase arrester system of 500 kV intelligent substation to build three kinds of resistance capacitance network for simulation analysis.The change rules of resistance capacitance network and the selected model(conductor quantity)are summarized and combined with monitoring data.The rationality of capacitive resistance network modeling is discussed.The results show that the resistance capacitance network of the typical 500 kV intelligent substation three-phase lightning arrester system,the lightning arrester needs to be segmented,the influence of the adjacent voltage transformer and the upper level bus line should be considered,and the simulation results can be better consistent with the field monitoring data.Then,according to the most reasonable resistance capacitance network model,the monitoring data are analyzed and calculated to diagnose the state of arrester.
关 键 词:避雷器阻容网络 变电站避雷器 相间干扰 状态诊断
分 类 号:TM862[电气工程—高电压与绝缘技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.141.38.5