自校准多通道红外辐射计的设计与性能测试  被引量:5

Design and performance test of self-calibration multichannel infrared radiometer

在线阅读下载全文

作  者:张允祥 李新[1] 李琛[3] 郑小兵[1] ZHANG Yunxiang;LI Xin;LI Chen;ZHENG Xiaobing(Key Laboratory of Optical Calibration and Characterization,Anhui Institute of Fine Mechanics,Chinese Academy of Sciences,Hefei 230031,China;University of Science and Technology of China,Hefei 230026,China;Bureau of Major R&D Programs,Chinese Academy of Sciences,Beijing 100864,China)

机构地区:[1]中国科学院安徽光学精密机械研究所,中国科学院通用光学定标与表征技术重点实验室,安徽合肥230031 [2]中国科学技术大学科学岛分院,安徽合肥230026 [3]中国科学院重大科技任务局,北京100864

出  处:《应用光学》2020年第4期743-753,共11页Journal of Applied Optics

基  金:国家重点研发计划(2018YFB0504604)。

摘  要:为满足遥感器热红外波段自动化观测定标的需求,研制了具有自动化观测能力的自校准多通道红外辐射计。该设备需具有以下特色功能:1)采用电机驱动镀金反射镜的设计,实现0°~90°仰角的大气下行辐射和地表辐亮度的测量,为消除大气下行辐射对反演地表温度的影响提供了技术手段;2)采用滤光轮分光的方法实现了6个光谱通道的自动设置,结合多通道温度与发射率分离算法可以实现场地温度与发射率的分离,为卫星遥感器热红外波段绝对辐射定标提供了2个关键因子;3)采用内置2个控温精度分别优于0.04 K和0.05 K、发射率均高于0.994,稳定性均优于0.0014的黑体实现内部探测器的实时辐射定标,有效地消除了内部背景辐射对辐射测量的影响,定标不确定度小于0.167%。等效测温不确定度为0.2 K(@303 K,11μm),为遥感器热红外波段场地自动化定标应用的开展奠定了基础。In order to meet the needs of automated observation calibration for remote sensor thermal infrared band,a self-calibration multichannel infrared radiometer with automated observation capability was developed.The equipment has the following features:1)the design of motor-driven gold-plated reflector was used to achieve the measurement of downward atmospheric radiation and surface radiance at an elevation angle of 0°~90°,which provided the technical means to eliminate the influence of downward atmospheric radiation on inversion surface temperature;2)the filter wheel spectrometry was used to realize the automatic setting of 6 spectral channels,and combined with the multichannel temperature and emissivity separation algorithm,the separation of site temperature and emissivity could be achieved,which provided 2 key factors for the absolute radiometric calibration of satellite remote sensor thermal infrared band;3)a black body with two built-in temperature control accuracy better than 0.04 K and 0.05 K,emissivity higher than 0.994,stability better than 0.0014 was used to achieve the real-time radiometric calibration of the internal detector,which effectively eliminated the influence of internal background radiation on radiation measurement.The calibration uncertainty is less than 0.167%,and the equivalent temperature measurement uncertainty is 0.2 K(@303 K,11μm),which lays the foundation for the application of site automated calibration for remote sensor thermal infrared band.

关 键 词:定标 自动化 辐射计 自校准 不确定度分析 

分 类 号:TP722.6[自动化与计算机技术—检测技术与自动化装置]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象