检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:姚凯宁 王若曦 岳海振[1] 王美娇[1] 王翰林 弓健[1] 张艺宝[1] 吴昊[1] YAO Kaining;WANG Ruoxi;YUE Haizhen;WANG Meijiao;WANG Hanlin;GONG Jian;ZHANG Yibao;WU Hao(Key Laboratory of Carcinogenesis and Translational Research(Ministry of Education/Beijing),Department of Radiotherapy,Peking University Cancer Hospital&Institute,Beijing 100142,China)
机构地区:[1]北京大学肿瘤医院暨北京市肿瘤防治研究所放疗科,恶性肿瘤发病机制及转化研究教育部重点实验室,北京100142
出 处:《中国医学物理学杂志》2020年第7期822-827,共6页Chinese Journal of Medical Physics
基 金:北京市自然科学基金(1174016,1202009);北京市属医院科研培育计划项目(PX2019042);中央高校基本科研业务费/北京大学临床医学+X青年专项(PKU2020LCXQ019)。
摘 要:目的:对比双面膜固定条件下,外轮廓自动搜索参数设置引入的体积差异对靶区和危及器官的剂量学影响。方法:选取25例双面膜固定的全脑放疗患者,保持其他搜索条件不变的前提下,改变外轮廓搜索条件(平滑度、CT值阈值和后处理方法)并重新进行剂量计算,共计9种方案。对比改变参数后的计划与默认设置计划(Default)靶区和危及器官的剂量差异。结果:搜索条件中的平滑度和CT值对外轮廓和靶区的剂量指标影响较大。在DSL0、DSL1、DSL2、HU-550和HU-750计划中,靶区的Dmean和外轮廓的Dmax变化较明显;外轮廓Dmean的变化均值在HU-750计划中超过400 cGy。结论:Eclipse计划系统默认的搜索外轮廓的方式不适合所有情况,低平滑度和低HU限值条件搜索的外轮廓对剂量影响较大。针对全脑双面膜的患者外轮廓搜索条件,本研究建议平滑度为1,HU阈值为-550 HU。Objective To analyze the effects of the volume differences introduced by the parameter setting of automatic Body search strategy on the dosimetric calculations for planning target volume(PTV)and organs-at-risk in patients immobilization with doublesided mask.Methods Twenty-five patients immobilized with double-sided mask for whole-brain radiotherapy were enrolled in the study.Keeping the other parameters unchanged,the Body search conditions(smoothing level,CT value threshold and postprocessing method)were changed for dose calculation.Atotal of 9 treatment schemes were designed.The dosimetric differences in PTV and organs-at-risk between parameter-changed plans and Default plan were analyzed.Results The smoothing level and CT values had significant effects on the dosimetric parameters of Body and PTV.In DSL0,DSL1,DSL2,HU-550 and HU-750 plans,the Dmean of PTV and the Dmax of Body was changed obviously.The average change in Body Dmean exceeded 400 cGy in HU-750 plan.Conclusion The default Body search strategy in the Eclipse treatment planning systemis not suitable for all situations.The Body search under lowsmoothness and lowHUhas a great effect on dose calculation.For the patient immobilizedwith doublesidedmask for whole-brain radiotherapy,the recommended smoothness level and HU threshold are 1 and-550 HU,respectively.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.117.82.179