斯坦福UC系列发电机不发电故障分析与排除  

Trouble Shooting Method for Voltage Abnormality of Stanford UC Series Generator

在线阅读下载全文

作  者:王杰[1] 孙中华 王瑞成 刘桃生 Wang Jie;Sun Zhonghua;Wang Ruicheng;Liu Taosheng(Electromechanical Department,Naval Petty Officer Academy,Bengbu 233012,Anhui,China;Naval Aeronautical Engineering Institute Qingdao Branch,Qingdao 266041,Shandong,China)

机构地区:[1]海军士官学校机电系,安徽蚌埠233012 [2]海军航空工程学院青岛校区,山东青岛266041

出  处:《船电技术》2020年第7期46-49,共4页Marine Electric & Electronic Engineering

摘  要:斯坦福自励发电机作为主电源或应急电源应用在很多领域,市场保有量大,其不发电故障排除困难。本文以使用SX440型自动调压器的UC系列自励发电机为研究对象,在分析其结构与工作原理的基础上,对其不发电故障的原因进行梳理,并以故障树流程图的方式给出了排除故障的操作步骤,为人员维修该类故障提供指导和借鉴。As the main power or emergency power supply, the stanford self-excited generators are applied in many fields, with a large market share, but it is difficult to troubleshoot its abnormal voltage. Based on the analysis of its mechanism and working principle, and taking the self-excited generator with sx440 automatic voltage regulator as the research object, this article focuses on its abnormal voltage faults, and gives the troubleshooting steps in the form of fault tree flow chart for different faults,which c ould provide guidance and reference for technicians.

关 键 词:斯坦福发电机 不发电 故障树 流程图 

分 类 号:TM343[电气工程—电机]

 