检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:任尚坤 夏瑞芳 刘希海 曹伟 王继松 张荣成 陈峰 杨涛 REN Shang-kun;XIA Rui-fang;LIU Xi-hai
机构地区:[1]华电章丘发电有限公司,山东章丘250216 [2]南京常荣声学股份有限公司,江苏南京210008
出 处:《节能》2020年第6期49-51,共3页Energy Conservation
摘 要:华电章丘发电有限公司3~#炉SCR的催化剂的脱硝效率较差,催化剂上积灰严重。在3~#炉B侧催化剂的三层催化剂上分别对装2套可调频高声强声波吹灰器后,停炉检修时发现B侧催化剂上积灰明显少于A侧催化剂上积灰。通过对两侧的监测数据发现,B侧的SCR氨逃逸率、催化剂压差、脱硝效率等指标全面优于A侧。Huadian Zhangqiu Power Generation Co.Ltd.3~#furnace SCR catalyst denitrification efficiency is poor,and the ash accumulation on the catalyst is serious.After installing two sets of adjustable frequency high-acoustic sonic soot blowers on the three-layer catalyst of the 3~#furnace B side catalyst,it was found that the ash accumulation on the B side catalyst was significantly less than that on the A side catalyst when the furnace was shut down for maintenance.By comparing the monitoring data on both sides,it is found that the SCR ammonia escape rate,catalyst pressure difference,out-of-stock efficiency and other indicators on the B side are better than the A side.
分 类 号:TU831[建筑科学—供热、供燃气、通风及空调工程]