750kV变电站主变压器空间声场分布研究  被引量:1

Research on spatial acoustic field distribution of transformer of 750kV substation

在线阅读下载全文

作  者:张旭博 雷洋 龚洁 ZHANG Xubo;LEI Yiang;GONG Jie

机构地区:[1]中国电力工程顾问集团西北电力设计院有限公司,陕西西安710075

出  处:《电力科技与环保》2020年第4期41-43,共3页Electric Power Technology and Environmental Protection

摘  要:变压器是变电站内主要的噪声源之一。以某750kV变电站变压器噪声实测数据为基础,结合工程实际,基于Cadna/A噪声预测软件模拟得到变压器两种典型声源分布下空间声场等声级线的分布图,并模拟得到三相(台)主变在两种声源分布下的衰减曲线。为研究变电站噪声预测、声环境影响分析评价及噪声治理方案设计提供参考。Transformers are the main acoustic source of substations.Based on the measured data of transformer noise of a 750kV substation,combined with engineering practice,using Cadna/A noise prediction software,the distribution of sound level lines of sound field and attenuation curve of the main transformer under two typical acoustic source distributions of transformers is obtained.That provide reference for the study of substation noise prediction,acoustic environmental impact analysis and evaluation and the design of noise control.

关 键 词:变压器 声环境影响分析评价 声场分布 

分 类 号:X593[环境科学与工程—环境工程]

 