检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:杨超越[1,2] 易铧 刘可 何金龙[1,2] 倪伟 常宏岗[1,2] 胡超 胡天友 陈世明[5] 陈文科 YANG Chaoyue;YI Hua;LIU Ke;HE Jinlong;NI Wei;CHANG Honggang;HU Chao;HU Tianyou;CHEN Shiming;CHEN Wenke(Research Institute of Natural Gas Technology,PetroChina Southwest Oil&Gasfield Company,Chengdu 610213,Sichuan,China;National Energy R&D Center of High Sulfur Gas Exploitation,Chengdu 610213,Sichuan,China;Gas Field Development Management Department,PetroChina Southwest Oil&Gasfield Company,Chengdu 610056,Sichuan,China;Chongqing Natural Gas Purification Plant General,PetroChina Southwest Oil&Gasfield Company,Chongqing 401220,China;CDB Operating Company,PetroChina Southwest Oil&Gasfield Company,Chengdu 610056,Sichuan,China)
机构地区:[1]中国石油西南油气田公司天然气研究院,四川成都610213 [2]国家能源高含硫气藏开采研发中心,四川成都610213 [3]中国石油西南油气田公司气田开发管理部,四川成都610056 [4]中国石油西南油气田公司重庆天然气净化总厂,重庆401220 [5]中国石油西南油气田公司川东北作业公司,四川成都610056
出 处:《化工进展》2020年第8期3371-3379,共9页Chemical Industry and Engineering Progress
基 金:中国石油天然气股份有限公司重大科技专项与应用(2016E-0610)。
摘 要:针对常规甲基二乙醇胺(MDEA)脱硫溶剂对有机硫脱除率不高、含有机硫的天然气脱硫后不能满足GB17820—2018对管输气要求的问题,中国石油西南油气田公司天然气研究院开发了高效有机硫脱除溶剂CT8-24,在室内研究以及中间放大试验的基础上,在重庆天然气净化总厂引进分厂400×10^4m^3/d装置上进行了工业应用。考察了溶剂在不同循环量、处理量、吸收塔板数以及再生温度等条件下的吸收性能,确定了较适宜的工艺操作参数。结果表明,将引进分厂400×10^4m^3/d装置原用的MDEA水溶液改换为CT8-24后,装置运行平稳。在35层吸收塔板下,产品中H2S含量<6mg/m^3,总硫<20mg/m^3,达到GB17820—2018的要求。同时分析研究了CT8-24类物理-化学溶剂对MDEA脱硫装置的适应性,为其他净化厂气质达标改造工作奠定了坚实基础。Due to the low removal rate of organic sulfur by MDEA,it cannot meet the requirements for pipeline natural gas in GB 17820—2018.To solve this problem,the natural gas research institute has developed an efficient organic sulfur removal solvent(CT8-24).On the basis of indoor research and intermediate scale-up test,the industrial application is carried out on the 400×10^3 m^3/d unit imported from Chongqing natural gas purification plant of PetroChina Southwest Oil and gas field company.The absorption performance of the solvent under different absorption tower plate number,regeneration temperature and circulation quantity of the solution was investigated,and the appropriate process parameters were determined.The results of industrial application showed that the operation of the unit was stable after transforming MDEA aqueous solution into CT8-24 solvent.Under the 35 layer absorption tray,the H2 S content in the product was less than 6 mg/m^3 and the total sulfur was less than 20 mg/m^3.The product gas met the latest requirements of GB 17820—2018.In addition,the adaptability of physicalchemical solvent to MDEA desulfurization unit was studied,which laid a solid foundation for the transformation of other purification plants.
分 类 号:TE644[石油与天然气工程—油气加工工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.28