检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:吴集迎 马益民 曹文胜 WU Jiying;MA Yimin;CAO Wensheng(College of Mechanical and Energy Engineering,Jimei University,Xiamen 361021,Fujian,China;Cleaning Combustion and Energy Utilization Research Center of Fujian Province,Xiamen 361021,Fujian,China)
机构地区:[1]集美大学机械与能源工程学院,福建厦门361021 [2]福建省清洁燃烧与能源高效利用工程技术研究中心,福建厦门361021
出 处:《化工学报》2020年第8期3789-3796,共8页CIESC Journal
基 金:国家自然科学基金项目(51879117)。
摘 要:为高效利用沼气资源并减轻环境污染,构建了基于沼气机驱动的风冷热泵能源综合利用实验装置,重点研究了蒸发温度、冷却水量、沼气机转速等参数对系统性能的影响。实验测试结果表明:冷凝器总负荷随蒸发温度及冷却水量的增加而增大,但增幅较小;回收的沼气机余热随蒸发温度的升高而降低,但降幅较小,通过增大冷却水量可以提高沼气机余热的回收率,同时也增大了系统总供热量;冷却水量对系统性能系数(COP)的影响不具有单调性,在同一工况下,存在一个最佳冷却水量;冷却水量对系统一次能源利用率(PER)的影响幅度不同,冷却水量大时,PER的增幅反而较小。实验工况下,系统COP最高可达5.15,PER最高可达1.68。To efficiently use biogas resources and reduce environmental pollution, an experimental device for energy comprehensive utilization of airsource heat pump driven by a biogas engine was constructed, focusing on the effects of evaporation temperature, cooling water flow rate, biogas engine speed and other parameters on system performance. Experiment results show that while total condenser load increases with rising evaporator temperature and cooling water flow rate, the rate of increase is small. The recovered biogas engine waste heat decreases with rising evaporator temperature although the rate of decrease is not large, but cooling water flow rate increase can improve the recovered rate of biogas engine waste heat and the total heating capacity of the system at the time.Effect of cooling water flow rate on system coefficient of performance(COP) is not monotonic, and there exists an optimum cooling water flow rate under certain working conditions. Different cooling water flow rate has different effect on primary energy ratio(PER), and lesser PER increase corresponds larger cooling water flow rate. Under the experiment conditions, the maximum system COP and PER are 5.15 and 1.68 respectively.
关 键 词:再生能源 热力学过程 沼气机 性能实验 蒸发温度 冷却水量
分 类 号:TU832.2[建筑科学—供热、供燃气、通风及空调工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222