燃煤电厂亚临界机组低温过热器管泄漏原因分析  被引量:1

Reason for Leakage of Low Temperature Superheater Pipe in Subcritical Units for a Coal fired Power Plant

在线阅读下载全文

作  者:魏然 WEI Ran

机构地区:[1]国电科学技术研究院有限公司银川分公司,宁夏银川750000

出  处:《青海电力》2020年第2期66-68,共3页Qinghai Electric Power

摘  要:针对某燃煤电厂亚临界机组运行中低温过热器20 G管发生泄漏原因进行理化检验和分析,并提出建议。结果表明:低温过热器管在弯管加工过程中,由于加工工艺不当造成内壁出现微裂纹,在外部环境与材料自身应力综合作用下逐步扩展,最终穿透管壁导致泄漏。the cause of leakage of low temperature superheater pipe 20G in subcritical units for a coal fired power plant is examined and analyzed,and some suggestions are put forward.The results show that microcracks appear on the inner wall of the low temperature superheater pipe due to the improper processing technology in bending.The microcracks gradually expand under the combined effect of the external environment and the material's own stress during the operation process,and finally leak through causing the leakage..

关 键 词:燃煤电厂 亚临界 低温过热器管 泄漏 裂纹 弯制工艺 

分 类 号:TM314.9[电气工程—电机]

 