检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:吴晓欣[1] 何怡刚 段嘉珺 张慧[1] 曾昭瑢 WU Xiaoxin;HE Yigang;DUAN Jiajun;ZHANG Hui;ZENG Zhaorong(School of Electrical Engineering and Automation,Wuhan University,Wuhan 430072,China)
机构地区:[1]武汉大学电气与自动化学院,湖北武汉430072
出 处:《电力自动化设备》2020年第8期184-190,共7页Electric Power Automation Equipment
基 金:国家自然科学基金资助项目(51977153,51977161,51577046);国家自然科学基金重点资助项目(51637004);国家重点研发计划“重大科学仪器设备开发”资助项目(2016YFF0102200);装备预先研究重点项目(41402040301)。
摘 要:当前基于油中溶解气体分析(DGA)的变压器故障诊断方法往往仅考虑单一时刻数据点,容错性差,难以充分挖掘在线监测数据的时序信息。提出一种考虑变压器油特征参量序列间复杂关系的基于双向长短时记忆(Bi-LSTM)网络的变压器故障诊断方法。首先构建了变压器油特征参量序列,基于序列数据构建了Bi-LSTM变压器故障诊断模型。工程实际中不同变压器油特征参量序列长短不一,需通过排序、分组填充对模型输入进行重构改进,然后对超参数进行优化。基于同一自建数据库对比所提方法与其他方法,结果表明:经过数据重构后所提方法的准确率可达91.9%;当特征指标数量减少约2/3时,所提方法的准确率仅下降约1%,而其他方法的准确率平均下降约6%;当采样数据存在10%的随机错误时,所提方法诊断准确率仅下降2%~6%,且通过改变隐藏层的数量可得到改善。Transformer fault diagnosis methods based on DGA(Dissolved Gas Analysis)are commonly just consider data obtained at a single moment,which is susceptible to data errors and cannot fully mine the online monitoring data sequence information.Aiming at this problem,a Bi-LSTM(Bi-directional Long ShortTerm Memory)network based transformer fault diagnosis method considering the complex correlation relationship among the characteristic parameter sequences of transformer oil is proposed.Firstly,the characteristic parameter sequences of transformer oil are constructed,and then the Bi-LSTM-based transformer fault diagnosis model is constructed based on the sequence data.Considering the different length of the sequences in engineering practice,the model inputs are reconstructed by sorting and group filling.The hyper-parameters are then optimized.Based on the same built database,the proposed method is compared with other methods.The results show that the diagnosis accuracy of the proposed method after data reconstruction can reach91.9%,and only drops by about 1%when the number of characteristic parameter decreased by about twothirds,while other methods decrease by about 6%on average.When the sampling data exists a 10%random errors,the diagnosis accuracy of the proposed method decreases by 2%to 6%,and can be improved by changing the number of hidden layers.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.68