混凝技术处理厌氧消化污泥脱水液试验研究  被引量:2

Experimental study on coagulation treatment of anaerobic digestion sludge dewatering solution

在线阅读下载全文

作  者:张轶凡[1,2] 徐博 张博文 聂英进 ZHANG Yi-fan;XU Bo;ZHANG Bo-wen;NIE Ying-jin(Tianjin Capital Environmental Protection Group Co.Ltd.,Tianjin 300381,China;Tianjin Caring Technology Development Co.Ltd.,Tianjin 300384,China;College of Environment and Municipal Engineering,Tianjin Chengjian University,Tianjin 300384,China;Key Laboratory of Water Quality Science and Technology,Tianjin 300384,China)

机构地区:[1]天津创业环保集团股份有限公司,天津300381 [2]天津凯英科技发展股份有限公司,天津300384 [3]天津城建大学环境与市政工程学院,天津300384 [4]天津市水质科学与技术重点实验室,天津300384

出  处:《天津工业大学学报》2020年第4期59-65,共7页Journal of Tiangong University

基  金:水体污染控制与治理科技重大专项(2015ZX07306001);天津市科技计划项目(19JCTPJC47000)。

摘  要:为满足厌氧氨氧化工艺对悬浮物(SS)和铁浓度的进水要求,采用混凝技术对厌氧消化污泥脱水液进行预处理。通过曝气试验和正交试验,确定了厌氧消化污泥脱水液的最佳曝气量、曝气时间和混凝工艺条件;基于单因素试验,得到最佳工艺条件为:快搅(250 r/min)90 s、慢搅(90 r/min)120 s、助凝剂投加时间30 s、静置15 min、聚合氯化铝(PAC)投加量20 mg/L、聚丙烯酰胺(PAM)投加量1 mg/L、pH值为7.0,此时厌氧消化污泥脱水液中的浊度和总铁去除率分别为97.63%和98.21%。由此可见,混凝技术处理后的出水不仅可以提高污染物的去除效果,还可以满足后续厌氧氨氧化工艺的进水要求。In order to meet the requirements of the suspended solids(SS)and iron concentration in the influent of anaerobic ammonia oxidation process,the coagulation technology was used to pretreat the sludge dewatering solution from anaerobic digestion.Through aeration test and orthogonal test,the optimal aeration intensity,aeration time and coagulation process conditions of anaerobic digestion sludge dewatering liquid were determined.Based on single factor test,the best process conditions were obtained as follows:(250 r/min)90 s of fast stirring,(90 r/min)120 s of slow stirring,30 s of coagulant aids dosing time,15 min of standing time,20 mg/L of polyaluminium chloride(PAC),1 mg/L of polyacrylamide(PAM),7.0 of pH value.At this time,turbidity and total iron removal rates in anaerobic digested sludge dewatering solution were 97.63%and 98.21%,respectively.The effluent treated by coagulation can not only improve the removal effect of pollutants,but also meet the influent requirements of subsequent anaerobic ammonium oxidation process.

关 键 词:混凝 厌氧消化污泥脱水液 正交试验 单因素试验 

分 类 号:X703[环境科学与工程—环境工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象