检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:马记 MA Ji(Huadian Laizhou Power Generation Co.,Ltd.,China Huadian Group,Laizhou 261400,Shandong,China)
机构地区:[1]中国华电集团华电莱州发电有限公司,山东莱州261400
出 处:《能源与节能》2020年第8期182-183,共2页Energy and Energy Conservation
摘 要:通过深入研究1000 MW超超临界二次再热机组冷态启动过程中影响脱硝投运的关键因素,从提高给水温度、提高送风温度、提高炉膛出口烟温等运行调整入手,充分利用各项有利条件,最终实现机组并网前SCR入口烟气温度达到脱硝投入条件,实现机组冷态启动过程中NOx全程不超标。Through in-depth study on the key factors affecting denitration during cold start-up of 1000 MW ultra supercritical secondary reheat unit,starting from the operation adjustment of increasing feed water temperature,air supply temperature and flue gas temperature at furnace outlet,taking full advantage of various favorable conditions,the flue gas temperature at SCR inlet reached the denitration input condition before the unit was connected to the grid,and NOx did not exceed the standard during the whole process of cold start-up of the unit.
关 键 词:超超临界 NOx 给水温度 送风温度 炉膛出口烟温
分 类 号:TM621[电气工程—电力系统及自动化] X773[环境科学与工程—环境工程]