检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:刘彩红[1] 林可可 李晓光[1] 汲燕波[1] LIU Cai-hong;LIN Ke-ke;LI Xiao-guang;JI Yan-bo(Department of Infectious Diseases Peking University Third Hospital,Beijing 100191,China)
机构地区:[1]北京大学第三医院感染疾病科,北京100191 [2]北京中医药大学护理学院,北京100029
出 处:《中华全科医学》2020年第10期1762-1765,共4页Chinese Journal of General Practice
基 金:北京市科技计划项目(D151100002115002)。
摘 要:目的评价红外额式体温计在筛查发热患者中的价值,并找出其用来判断发热的最佳界值,为临床使用红外额式体温计提供依据。方法固定专人测量北京大学第三医院发热门诊2018年6月1日-8月30日就诊的1176例患者体温,采用自身对照的方法,使用红外额式体温计与水银式体温计分别测量。结果1176例患者中,男性529例(45%),女性647例(55%),平均年龄(36.91±16.46)岁。Band-Alman结果显示额温腋温测量一致性较好。水银式体温计测量腋温为(38.31±0.67)℃,红外额式体温计测量额温为(37.30±0.77)℃,二者平均差值(1.01±0.64)℃(1=53.774,P<0.001)。体温正常组、低热组、中热组、高热组的腋温和额温差值分别为(0.25±0.55).(0.83±0.50)、(1.08±0.66).(1.33±0.70)℃,1值分别为2.180.35.721.36.760及25.710,均P<0.05。红外额式体温计测量体温的灵敏度为0.482,特异度为0.913。ROC曲线下面积AUC为0.73,P<0.001,95%CI为0.650~0.811。最大约登指数为0.477,所对应的界值为37.05℃。结论红外额式体温计测量体温与水银体温计所测得的腋温存在一定差异,前者比后者低。而且随着体温的升高,差异增大。红外额式体温计可在发热门诊中使用,由于临床使用红外额式体温计进行体温测定时读数只能到小数点后1位,但应以37.0℃作为初步判断患者是否发热的依据。Objective To evaluate the value and the optimal cut-off value of infrared forehead thermometer for fever screening.Methods Body temperatures of 1176 patients who visited the fever clinie from June lst to August 30th 2018 were measured using both infrared forehead thermometer and mercury thermometer.Results Among 1176 patients,529(45%)were males and 647(55%)were females,with the mean age of 36.91±16.46 years old.Bland-Altman results showed that the consistency of frontal temperature and axillary temperature was relatively good.The average temperature measured by the mercury thermometer was(38.31±0.67)℃,while the average temperature measured by the infrared forehead thermometer was(37.30±0.77)℃.The mean difference was(1.01±0.64)℃.Paired 1-test showed that t value was 53.774,P<0.001.The mean difference between the two types of temperatures for the normal temperature group,low fever group,moderate fever group and high fever group were(0.25±0.55),(0.83±0.50),(1.08±0.66)and(1.33±0.70)℃,respectively.The t values were 2.180,35.721,36.760 and 25.710,respectively,P<0.05.The sensitivity and specificity of using the infrared forehead thermometer to measure the body temperature were 0.482 and 0.913,respectively.The area under the ROC curve was 0.73,P<0.001,the 95%confidence interval was 0.650~0.811.The maximum value for the Youden index was 0.477,and the corresponding temperature was 37.05℃.Conclusion There is statistically significant dfference between the body temperatures measured by the infrared forehead thermometer and the mercury thernometer,with the former lower than the ltter.The higher the body temperature is,the more difference is.Since the temperature reading of infrared frontal thermometer can only be read to one decimal place in elinical practice,37.0℃ should be used as the basis for preliminary determination of whether the patient has fever.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.15