检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张素平[1,2] 王海平 修连喜[1] 黄巧妹[1] 梁桂荣 张忠诚 阮天福 ZHANG Su-ping;WANG Hai-ping;XIU Lian-xi;HUANG Qiao-mei;LIANG Gui-rong;ZHANG Zhong-cheng;RUAN Tian-fu(The Second Hospilal of longyan,Longyun 364000,China;The Graduale School of Flujian Medical University,Fuzhou 350122,China)
机构地区:[1]龙岩市第二医院,福建龙岩364000 [2]福建医科大学研究生院,福州350122
出 处:《中国药学杂志》2020年第15期1284-1288,共5页Chinese Pharmaceutical Journal
基 金:龙岩市科技计划立项资助(2017LY66)。
摘 要:目的建立高效液相色谱法测定血浆中替考拉宁(TEIC)总浓度(Ct)和游离浓度(Cf)的方法。方法游离浓度血浆样本经超滤离心管处理后进行HPLC分析。采用C1g色谱柱,以乙腈0.01·mL^-1磷酸二氢钠(25:75,磷酸调pH值至3.3)为流动相,检测波长240 nm,柱温35 C,流速1.0 mL·mL^-1,考察该方法的专属性、标准曲线、定量下限、精密度、回收率和稳定性。结果游离浓度在0.5~50μg·mL^-1内线性关系良好(y=12801x-2574.1,r^2=0.9998),定量下限为0.5μg·mL^-1,方法回收率为94.63%~103.72%,批内、批间RSD均<4.00%;总质量浓度在1.5625~100μg·mL^-1内线性关系良好(y=10576:x+9950.1,r^2=0.9998),定量下限为1.5625μg·mL^-1,方法回收率为94.55%~99.59%,批内、批间RSD均<4.00%。在室温放置10h、冻融循环3次和4℃冷藏72 h稳定性良好。结论本方法简便、准确、灵敏,适用于临床替考拉宁血药总浓度和游离浓度的检测及药动学的研究。OBJECTIVE To establish an HPLC method for the determination of total(Ct)and free(Cf)concentrations of teico-planin(TEIC)in plasma.METHODS For determing the free concentration,the plasma samples were prepared by ulrafiltration.A Cx colunn was used,with acetonitrile-0.01·mL^-1sodium dihydrogen phosphate(25:75,pH adjusted to 3.3 by phosphoric acid)as the mobile phase,the detection wavelength was set at 240 nm,the column temperature was maintained at 35 C,and the flow rate was 1.0·mL^-1.The speificity,linearity,the lower limit of quantitation,precession.recovery and stability of the developed meth-od were validated.RESULTS The free concentration was linear with in 0.5-50μg·mL^-1,the lower limit of quantification was 0.5μg·mL^-1,and the method recovery rate was 94.63%-103.72%。The intra-day and inter-day precision(RSD)were all less than 4.00%;the linearity was good with in the total concentration of 1.5625-100μg·mL^-1,the lower limit of quantification was 1.5625μg·mL^-1,the method reeovery rale was 94.55%-99.59%.The intra-day and inter day precision(RSD)were all less than 4.00%。The TEIC was all stability at the conditions of maintaining at room temperature for 10 h,after freeze-thaw cycle and keeping at 4℃ for 72 h.CONCLUSION The method is simple,accurate,and sensitive,and is suitable for the clinical determination of total and free concentrations of teicoplanin and the studly of pharmacokinetis.
分 类 号:R917[医药卫生—药物分析学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.229